QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Invitium Battery System Model BAT-24CM Locate Battery Housing Identify Connector Ports Install Battery Fuses OPERATIONS MANUAL USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Battery Disposal Specifications Planar Systems, Inc.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED Planar Systems, Inc. © 2004. All rights reserved. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. Planar provides this information as reference only. Reference to other vendors’ product does not imply any recommendation or endorsement.
QUICK LINKS Contents Contents Index Regulatory Compliance Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Product Information About the Invitium Battery System . . . . . . . . . . . . . . . . . . . . . . . 1 Warranty Locate the Battery Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GETTING STARTED Identify the Connector Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QUICK LINKS Product Information Contents Index Safety guidelines Regulatory Compliance Product Information The Invitium battery system is designed to ensure both the highest level of product quality and safety for the user. To maintain both quality and safety, follow the guidelines and instructions in this manual. Warranty • Use the battery system only as intended. • Do not place the battery system near a window.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED Cleaning guidelines The Invitium battery system continues to operate normally while being cleaned in a fashion normal for a hospital environment. Use a damp, mildly soapy cloth to clean the exterior chassis. Drip protection is provided in accordance with the IPX1 rating, defined in the IEC/EN60529 standard.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Invitium Battery System As a component of the Planar Invitium medical workstation, the Invitium battery system is designed specifically for point-of care use. It is modular, compact, and ergonomically suited for effective utilization in the medical environment. The battery system supplies a regulated +12 VDC to the Invitium medical workstation.
QUICK LINKS Contents Index Regulatory Compliance Locate the Battery Housing The Invitium battery system ships already installed on the Invitium cart. The power cord, USB cable, and output power cable are connected, and the output power fuse is installed. You need to install the two battery fuses before operation. In operation Check that all cords and cables are securely connected before you turn on the Invitium workstation. Do not block the vent holes on the battery housing.
QUICK LINKS Contents Index Identify the Connector Ports All external connections to the battery system are located on the rear of the battery enclosure. The design of the enclosure minimizes liquid ingress.
QUICK LINKS Contents Index Regulatory Compliance Install the Battery Fuses You need the two battery fuses and a screwdriver for this installation. About the battery fuses To install a battery fuse The Invitium battery system requires two 6 A fuses. These are available from any hardware store. 1 Push the fuse in until you feel the connection.
QUICK LINKS Contents Index Regulatory Compliance Charge the Battery This section provides basic information on battery operations. See specifications on battery charging, charging controller board, and power consumption efficiency for more information. Product Information Battery charging Warranty Plug the battery system into an AC power source for charging.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Battery discharging You discharge the battery by (1) disconnecting the battery system from the AC power source and (2) powering the load. When the battery has been discharged for a long period of time, it reaches a point at which it needs to cut off power to its load. The battery system communicates to the host computer and requests a safe shutdown or hibernation.
QUICK LINKS Contents Set Up the Power Management System Index All communications occur through the USB serial interface. These are displayed through the Windows Power Options Properties dialog box on the host computer. Regulatory Compliance To set up power management Product Information 1 Open the Control Panel and click the Power Options tool. Warranty GETTING STARTED Easier power management Unlike earlier Invitium battery systems, this system has no charge indicator panel.
QUICK LINKS 2 Click the Alarms tab on the Power Options Properties dialog box. Contents Low battery alarm Index Product Information User-selectable alarm that is audible or silent. The alarm is triggered when the battery charge level reaches its low battery limit. Warranty Critical battery alarm Regulatory Compliance User-selectable alarm that is audible or silent. The alarm is triggered when the battery charge level reaches its depth of discharge limit.
QUICK LINKS 4 Select the notification you want, one of the two types or both. Click OK. Contents Alarm action Index An alarm action to hibernate or shut down can be selected in the Power Options Properties menu. Regulatory Compliance Product Information Alarm notification Warranty You must select a notification for the alarm you choose. Selecting an alarm action or running a program is optional.
QUICK LINKS 5 Open the Power Meter tab to check the power status of each battery. Contents • Click the check box to see the details on a battery. Index • Click a battery icon for more information.
QUICK LINKS Contents Index Regulatory Compliance Replace the Battery To remove the battery system from the cart 1 Loosen the two screws on the front of the cart. 2 Loosen the screw on the back, and tuck the cables to the side. Product Information Warranty About the Battery System Locate Battery Housing Install Battery Fuses 3 Unplug the power cord, USB cable, and output power cable. Set Up Power Management The unit is heavily weighted toward the front of the cart.
QUICK LINKS Contents To replace the battery 1 Loosen the two screws and remove the retaining bracket. Replacement tips Use only Yuasa NP 12-12 or B&B EP 12-12 batteries. Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports 2 Detach the four battery terminal cable connectors and move them to the side.
QUICK LINKS To reinstall the battery system into the cart Contents 1 Push the battery system all the way into the housing area. Index 2 Plug in the power cord, USB cable, and power output cable. Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports Install Battery Fuses 3 Reinsert the two battery fuses. 4 Reinsert the three screws, one in the back and two in the front.
QUICK LINKS Troubleshooting Contents Index Problem Possible Cause Possible Solution Regulatory Compliance The battery system not functioning, no output power, does not charge when connected to AC power. AC power is not connected. Make sure power cord is connected properly Input fuse needs to be replaced. Replace fuse in input connector. Replace with UL recognized fuse 2 A, 250 VAC, fast acting, size 5 mm x 20 mm. Over-temperature protection is activated. Contact Planar.
QUICK LINKS Battery Disposal Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Industrial batteries contain lead and sulfuric acid, which are both considered “hazardous substances.
QUICK LINKS Battery System Specification Contents Index Regulatory Compliance Technical summary Product Information The battery system is a self-contained regulated power supply, battery, and charger unit, packaged in a sheet metal enclosure.
QUICK LINKS Battery requirements Contents Index Battery type Sealed lead acid; quantity – 2 Yuasa NP12-12 or B and B EP12-12 Regulatory Compliance Capacity 12 Ah each Output voltage range 12 V nominal 9.5 to 14.4 V Cycle life approx.
QUICK LINKS Four modes of the battery system Contents Index Charging mode The battery system is plugged into an AC power source. During charging mode, the attached load to the battery system is operational. The batteries charge. The cooling fan runs only when the unit is plugged into an AC power source. Running mode The batteries have some level of charge and the battery system is not plugged into an AC power source. During running mode, the attached load to the battery system is operational.
QUICK LINKS Power consumption efficiency Contents Index Regulatory Compliance The charging controller board has four levels of power consumption: charging, running, stand-by, and off. Charging mode The batteries are charged using a constant current/constant voltage algorithm. A constant current of 3.0 amps max is applied to each battery until the voltage on the battery reaches 14.4 V. The current exponentially decreases to maintain 14.4 V on the battery. The cooling fan is on during this cycle.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty Index A alarm critical battery 8 disabled 8 low battery 8 setting 8, 9 B Replace Battery battery about system 1 charging 5 connector ports 3 discharge protection 6 discharging 6 disposal 15 fuses 3, 4 housing 2 input power 3 maintaining system 11 models 1 output power 3 power consumption 19 reinstalling 13 removing 11 replacing 11, 12 specifications 16 thermal protection 6 USB serial port 3 Troubleshooting C GETTING STARTED
QUICK LINKS Overview of Standard Warranty Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting APPENDIXES Summary • Standard 1-year “repair and return” warranty on all Invitium Medical Workstations • Typical repair turnaround time of 10 business days • Repair facilities a
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Summary Limitations and Exclusions of Invitium Medical Workstations 1 2 3 4 5 Invitium warranty is valid only for the first consumer purchaser (non-transferable). Customer support Invitium warranty does not cover the battery cell(s), mouse, or keyboard. In North America, call 1 (866) PLANAR1 between 8 A.M. and 5 P.M.
QUICK LINKS Exclusion of Damages Contents THE LIABILITY OF PLANAR IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT.
QUICK LINKS Regulatory Information Contents Caution U.S. Federal Communications Compliance Statement Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing The Planar Invitium Battery (model BAT-24CM) have has been tested and found to comply within the limits of a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation.
QUICK LINKS Regulatory Compliance Contents This system has been tested and found to comply with IEC/CSA 601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1 medical standards by CSA. Index Because many medical offices are located in residential areas, the Invitium battery system, in addition to meeting medical requirements, has also been tested and found to comply with the limits for Federal Communications Commission (FCC) Class B computing devices in a typically configured system.
QUICK LINKS Contents Index Regulatory Compliance Product Information Warranty GETTING STARTED About the Battery System Locate Battery Housing Identify Connector Ports Install Battery Fuses USING THE BATTERY Charge Battery Set Up Power Management MAINTAINING THE BATTERY Replace Battery Troubleshooting The applicable safety standards for an MDD Class I device are IEC/EN60601-1: 1990 along with Amendments 1 and 2.
QUICK LINKS Contents Symbol explanations Following are explanations of the symbols found on the Invitium battery, model BAT-24CM). E226863 Index Regulatory Compliance Product Information Warranty UL 60601-1 CAN/CSA C22.2 NO.601.1 CLASS 8750 Product has been tested and certified with respect to electric shock, fire, mechanical and other specified hazards only in accordance with US 2601-1 and CAN/CSA C22.2 No. 601.1 and IEC 60601-1 for medical equipment.