VitalScreen 17.4" Display VS17.4SXAD / CM17.4SXAD OPERATIONS MANUAL www.planar.
Planar Systems, Inc. © 2003. All rights reserved. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. Planar provides this information as reference only. Reference to other vendors’ product does not imply any recommendation or endorsement. This document contains proprietary information protected by copyright.
iii Regulatory Compliance VitalScreen CSR This display has been tested and found to comply with IEC/EN 60601-1 and IEC/EN 60601-1-2 standards, and is certified to meet medical standard C22.2 No. 601.1-M1990 (C US Mark). The medical display, in addition to meeting medical requirements, has been tested and found to comply with the limits for Federal Communications Commission (FCC) Class B computing devices in a typically configured system since many medical offices are located in residential areas.
iv In summary, Planar Systems, Inc. is CE-marking these displays under the Medical Device Directive, which establishes compliance to the basic medical safety standards. However, EMC compliance can only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer.
v FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation.
vii Contents About This Manual .............................................................. ix Product Information ............................................................. x 1 The VitalScreen 17.4" Display ........................................... 1 VitalScreen CSR ...................................................................... 2 VitalScreen CR......................................................................... 2 Distinguishing the Displays .............................................
ix About This Manual Congratulations on your purchase of the VitalScreen display! This operations manual will help you set up, use, and maintain the VS17.4SXAD or CM17.4SXAD model properly. Retain this manual for future reference. Read this section carefully to learn how to handle the display safely and clean it correctly. It explains the symbols used on the products and the conventions used in this manual. Chapter 1 provides an overview of the VitalScreen display.
x | Product Information Product Information Safety Instructions Store the display in its original shipping carton when it is not in operation for extended periods of time. Also use the original packing materials and carton when shipping the display. • Do not place the display near a window. Exposing the display to rain, water, moisture, or constant direct sunlight can damage it. • Do not place anything on top of the display-to-computer signal cord.
Product Information | xi Cleaning Instructions The VitalScreen display will continue to operate while being cleaned in a fashion normal for a hospital environment. This means cleaning the display with a damp, mild soapy cloth. The VitalScreen withstands nonabrasive cloths and cleaning solutions used in hospital for like equipment. This cleaning typically includes warm water and mild detergent for all surfaces or 70 percent isopropyl alcohol for the touchscreen surface.
xii | Product Information Symbol Explanations This table explains the symbols appearing on the display or power supply adapter. This symbol… Indicates… Proof of conformity to applicable European Economic Community Council directives and two harmonized standards published in the official journal of the European Communities. The product has been tested to specific requirements of medical or ITE device standards.
The VitalScreen 17.4" Display The architecture of the VitalScreen CSR and VitalScreen CR displays incorporate an active matrix liquid-crystal display (AMLCD) panel that produces a bright, high-contrast image with low radiation emission. This technology greatly reduces the radiation-related health concerns associated with cathode-ray tube (CRT) monitors. Each VitalScreen is a high-resolution color display designed to be versatile and easy to use.
2 | The VitalScreen 17.4" Display VitalScreen CSR This display has been designed, tested, and certified for use within the patient vicinity. It has lower electric discharge, thus reducing the likelihood of electric shock. The display is certified to UL-2601, IEC 60601-1, and other representatives of the most stringent electric discharge certifications available. In addition, the interface buttons on the front panel are sealed by a plastic membrane, allowing simpler and safer cleaning.
The VitalScreen 17.4" Display | 3 Selecting a Workspace Before unpacking the display, prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area that is relatively free of glare from sunlight or other sources of bright light. The display is cooled by natural convection. For best performance, do not block the cooling vents.
4 | The VitalScreen 17.4" Display Identifying the Components The VitalScreen CSR and VitalScreen CR displays provide easy access to all controls and peripheral ports. The following illustrations of the screen and the front and back panels identify the display controls and ports. 17.4" LCD screen LCD screen A 17.4-inch diagonal AMLCD. The screen supports most display standards from 640 x 480 VGA to 1280 x 1024 SXGA. VS17.4SXAD / CM17.
The VitalScreen 17.4" Display | 5 Front panel Power switch / Onscreen display Function buttons Adjustment buttons Power ON indicator VS17.4SXAD / CM17.4SXAD (020-0168-00B) Dual function button to control display power and access the OSD menu. Press this button for 2 seconds to turn the display ON or OFF. When the display is ON, press this button once to access the OSD menu. UP and DOWN arrows to navigate the OSD menus. When the OSD menu displays, press these buttons to select a control function.
6 | The VitalScreen 17.4" Display Back panel Locking 4-pin power connector Connect the low-voltage cable from the power adapter to this port. USB downstream ports (2) Connect peripherals (e.g., keyboard, 2 mouse) to these ports, if desired. USB upstream port (1) Connect the USB cable from the 3 computer to this port, if desired. Audio input jack Connect the system audio lineout to this port to listen to the system audio 4 on the display stereo speakers.
Installing the Display To install the VitalScreen CSR or VitalScreen CR display, first connect the power supply unit. Next, connect the video cable. Then choose whether to connect optional stereo speakers and touch screen. Safety Precautions Follow these safety precautions when connecting the display. • Plug the power adapter into a grounded power outlet. • Use a surge protector between the AC adapter and the electrical wall outlet to prevent sudden current variations from reaching the display.
8 | Installing the Display Connecting the Display to the System 1 Turn off power to the computer, camera, or other output source, and to the display. 2 Connect the appropriate video cable from the display to the video port on the output source. 3 Make sure the video cable connector is securely connected to the video port on the output device. 4 Turn on the display first, then turn on the output device. 5 Set the output device to a supported resolution, if applicable.
Installing the Display | 9 Connecting a Video Device Use the following instructions if you are hooking up a camera, VCR, or other S-Video or Composite Video device, and not using the VGA or DVI input simultaneously. These instructions apply to S-Video and Composite Video input-equipped displays only. 1 Press the Power/Menu button until the Power ON indicator blinks. After a moment, a No Signal Coming message appears. 2 Wait for the No Signal Coming message to disappear, approximately 3 to 5 seconds.
10 | Installing the Display Power Management System The VitalScreen CSR and VitalScreen CR displays comply with the VESA Display Power Management Signaling (DPMS) standard. This standard provides four power-saving modes, based on the display detecting the horizontal or vertical sync signals. This table describes the four modes.
The Display Controls Read this chapter carefully to use your VitalScreen CSR or VitalScreen CR display efficiently and effectively. Using the Onscreen Display The onscreen display (OSD) makes adjusting the display settings quick and easy. Use the OSD to adjust the brightness, contrast, volume, position, and language for the options in the display. You can access the OSD whenever both the computer and display are on. If the computer is off or in power-saving mode, the OSD is inaccessible.
12 | Installing the Display Main menu The following table describes the main menus of the onscreen display. The Main Menus Basic setting Change brightness, contrast Position Change the display attributes Auto-adjust Auto-adjust the display parameters to optimum values (not available for digital mode) Color temperature Adjust the color settings Miscellaneous Audio volume, OSD H-position, OSD V-position, display mode, FW (firmware) version Video Switch to video input port.
Installing the Display | 13 Function menus The following tables describe the function menus of the onscreen display. Basic Setting (Available in analog and/or digital mode) Contrast Adjust the contrast level of the display Analog Digital Brightness Adjust the brightness of the display’s backlight Analog Digital Video level Auto adjusts video level when selected Analog Gamma Gamma curve adjustment, ranging from 0.85 to 1.
14 | Installing the Display Color Temperature (Analog mode only)1 Color 9300 Set the color temperature of white to 9300 degrees Kelvin Color 6500 Set the color temperature of white to 6500 degrees Kelvin Color user Enable "User Color" selection, and adjust individual RGB levels R Adjust red contrast G Adjust green contrast B Adjust blue contrast To main menu 1 Three sets of color temperature settings are available: two for standard settings and one for user adjustment.
Installing the Display | 15 S-Video and Composite Video Settings These functions are active on the VitalScreen onscreen display when the display is in S-Video or Composite Video mode. This option is available only on the VitalScreen 17.4" CSR display. Settings The settings are selected with the Function buttons. Select the UP ( ) or DOWN ( ) arrow. Change the settings with the Adjustment buttons. Select the PLUS ( ) or MINUS ( ) control.
16 | Installing the Display Onscreen Display Lockout Both displays incorporate an OSD lockout function that you toggle active or inactive. Pressing three controls — Function DOWN ( ), Adjust PLUS ( ), and Adjust MINUS ( ) — simultaneously locks out the OSD from being enabled by the power control. Attempts to enable the OSD result in an “OSD locked” message only. To unlock the OSD, press the same three controls in the same manner.
Installing the Display | 17 Supported Video Modes Item Standard Resolution Dot Clock (MHz) Vertical Scanning Frequency (Hz) Horizontal Scanning Frequency (kHz) Sync Polarity or Composite Sync (H/V) Operating Mode 1 NEC PC98 640x400 25.20 70.15 31.50 -/- A/D 2 NEC PC98 640X400 21.05 56.42 24.83 -/- A 3 MAC 13" mode 640x480 30.24 66.67 35.00 -/- A/D 4 MAC 16" mode 832x624 57.28 74.55 49.73 -/- A/D 5 MAC 17" mode 1024x768 80.00 75.02 60.
Technical Information VitalScreen 17.4" CSR/CR Specification Display panel 17.4-inch (442-mm) SXGA active matrix LCD Display colors Full color supporting 8-bits/color Dimensions (W x H x D) Landscape mode Portrait mode 18" x 18" x 8.5" (457 mm x 457 mm x 216 mm) 15" x 19.5" x 8.5" (381 mm x 495 mm x 216 mm) Weight 20 lb (9 kg) Display area (W x H) 13.6" x 10.9" (345.6 mm x 276.48 mm) Response time 25 milliseconds Wht>Blk @ 25 milliseconds max.
Troubleshooting PROBLEM: Display is unclear and unstable This procedure is for users of analog VGA. This LCD device comes pre-adjusted with standard VGA timing. Due to output differences among various VGA cards, you may initially experience an unclear and unstable display when a new display mode or new VGA card is detected. To correct the problem, follow these steps: 1 Apply the Auto-Adjust option in the OSD menu for the display to adjust automatically to the video signal.
21 Index A adjustment functions, quick, 14, 15 assistance, technical, 24 B back panel, 6 cleaning instructions, xi components, identifying, 4 connecting AC power to display, 7 display to system, 8 optional touch screen, 9 video device, 9 controls, display, 11 conversion, mechanical, 10 customer support, 24 CVBS and S-video modes, 16 D display components, 4 connecting AC power, 7 connecting to system, 8 controls, 11 installing, 7 onscreen lockout, 16 onscreen main menu, 11, 12 description of, 1, 2 specifica
23 Description of Warranty Planar Systems, Inc. (Planar) warrants that the goods sold hereunder will be free of defects in materials and workmanship, and such goods will substantially conform to the specifications furnished by Planar, and to any drawings or specifications furnished to Planar by the Buyer if approved by Planar. This warranty shall be effective only if Planar receives notice of such defect or nonconformance during the period of the warranty.
24 The warranty set forth above shall not be enlarged, diminished, or affected by, and no obligation or liability shall arise from, Planar, any authorized dealer, or any other person’s rendering of technical advice, assistance, or services in connection with the Buyer’s order of the goods furnished hereunder. The Buyer is not relying on skill or judgment of Planar to select or furnish suitable goods.
25 Ordering Information VitalScreen CSR Part Number VS17.4SXAD 17.4-inch SXGA VitalScreen Medically Certified Display (non-touch) with desk stand and U.S. power cord 996-0497-00 VS17.4SXAD 17.4-inch SXGA VitalScreen Medically Certified Display (non-touch) with desk stand and European power cord 996-0497-01 VS17.4SXAD 17.4-inch SXGA VitalScreen Medically Certified Display (non-touch) with standard mounting (VESA compatible, 75 mm) and U.S. power cord 996-0497-02 VS17.4SXAD 17.
26 VitalScreen CR Part Number CM17.4SXAD 17.4 SXGA VitalScreen CR (non-touch) with desk stand and U.S. power cord 996-0514-00 CM17.4SXAD 17.4 SXGA VitalScreen CR (non-touch) with desk stand and European power cord 996-0514-01 CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (non-touch) with standard mounting (VESA compatible, 75 mm) and U.S. power cord 996-0514-02 CM17.4SXAD-TR 17.4 SXGA VitalScreen CR (non-touch) with standard mounting (VESA compatible, 75 mm) and European power cord 996-0514-03 CM17.
North and South America Sales Europe and Asia-Pacific Sales Planar Systems, Inc. 1195 NW Compton Drive Beaverton, OR 97006-1992 +1 (503) 748-1100 phone +1 (503) 748-1493 fax sales@planar.com tech_support@planar.com Planar Systems, Inc. Olarinluoma 9, P.O. Box 46 FIN-02201 Espoo, Finland +358 9 420 01 phone +358 9 420 0200 fax intlsales@planar.com intltech_support@planar.