Specifications

________________________________________________________________
V1.0
17 / 21
Document 020-1156-00 Rev B
Example: Set Mute-OFF command (ASCII)
Name Length Command
Value1
Value2
Value3
CR
Byte Count
5 6 0 0 1 00D
Bytes order
1 2 3 4 5 6
LCD Monitor will send “+” (02Bh) and “CR” bytes to PC after receiving a valid command.
LCD Monitor will send “-” (02Dh) and “CR” bytes to PC if the command is not valid.
Value Range:
Three bytes ASCII value range
Command
Code:
Function command code in ASCII
set command table
Set Function
Len
Value Range
Comments
Code
(Hex)
(Three ASCII
bytes)
Picture mode 5 81
000: STANDARD
001:
VIVID
002:
CINEMA
003: USER
Contrast 5 23
000 ~ 100
Brightness 5 24
000 ~ 100
Color 5 82
000 ~ 100
Tint 5 83
000 ~ 100
Sharpness 5 25
000 ~ 010
Backlight
5 84
000 ~ 100
Step : 20 for OSD
display range 0~5
DCR
5 85
000: OFF
001: ON
Color Temp
5 86
000: 12000K
001: 9300K
002: 6500K
004: User
Input Resolution
5 87
000: AUTO
VGA only
001: 1024x768
002: 1280x768
003: 1360x768
004: 1366x768
Volume
5 35
000 ~ 100