Copyright © 2003, Planar Systems, Inc. All rights reserved. Corporate Headquarters Planar Systems, Inc. 1195 N.W. Compton Drive Beaverton, OR 97006-1992 USA Phone: +1 (503) 748-1100 Fax: +1 (503) 748-1493 Americas Medical Sales Planar Systems, Inc. 400 Fifth Avenue Waltham, MA 02451-8738 USA Phone: +1 (781) 895-1155 Fax: +1 (781) 895-1133 Europe, Middle East, and Africa Medical Sales Planar Systems N.V.
U.S. Federal Communications Commission (FCC) Requirements This device was tested and complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
European Union Declaration of Conformity for Medical Applications A Declaration of Conformity exists for these products. To obtain a copy, contact Planar and request the “Declaration of Conformity” document number below. • Tk7 – 001-0014-04 • Tn4 – 001-0014-09 Certifications • • • • IEC/EN 60601-1:1990 + A1 + A2 for sale to the medical market IEC 60601-1-2:2001 as it applies to this system (informative data) Underwriters Laboratory to medical standards UL 2601-1 and CAN/CSA C22.2 No. 601.
Warranty Information Planar Systems, Inc. warrants that the goods sold hereunder are free of defects in materials and workmanship, and such goods substantially conform to the specifications furnished by Planar and to any drawings or specifications furnished to Planar by the Buyer if approved by Planar. This warranty is effective only if Planar receives notice of such defect or nonconformance during the period of the warranty.
About This Manual Read this manual before you unpack your Planar Invitium™ medical workstation. Chapter 1, Overview Intended use, components, options, and mounting solutions Chapter 2, Installing the Invitium Setting up and connecting Chapter 3, Troubleshooting Problem solving Audience This manual assumes you have experience installing and using computers. Refer technical issues to your Invitium vendor or system administrator.
Clean the Display Drip protection is in accordance with the IPX1 rating defined in the IEC/EN60529 standard. 1 Dampen a soft cloth with an approved cleaning solution. 2 Wipe the screen lightly until no residue remains. Note Do not spray cleaners directly on the screen. Approved cleaning solutions • WexCide • Ovation • Fantastic • Formula 409 • 1.6% aqueous ammonia • 70% isopropyl alcohol • “Green soap” USP (United States Pharmacopoeia) • Cidex (2.4% glutaraldehyde solution) • 0.
Contents Chapter 1: Overview.................................................................................. 1 Standard Equipment ................................................................................................................1 Optional Equipment .................................................................................................................2 System Configuration...............................................................................................................
Overview Your Planar Invitium medical workstation is designed for point-of-care use in the medical environment. With appropriate cables and AC power adapter or battery pack, the Invitium complies with applicable safety and regulatory EMC standards worldwide.
Optional Equipment Equipment Description Keyboard PS/2 or USB-compliant keyboard. Mouse PS/2 or USB-compliant mouse. Power Adapter External, 12-volt, double-insulated power adapter works from 90 to 240 Vac at 50 to 60 Hz. Equipped with an IEC320 appliance coupler, attached power cable, and U.S. or European medical-grade 3 m power cable. Light-emitting diode (LED) indicates power. Input voltage range meets U.S. and European standards.
System Configuration The configuration for some models may differ slightly. Invitium Workstation Clamshell cover (open below to show connections) Wireless PC card PC card slots Power Video/ ports audio Microphone input COM ports Antenna 1 3 2 4 USB ports Ethernet PC audio Keyboard (line) input Central processing unit (CPU) The Invitium uses convection cooling, in which internal thermal management directs heat to an array of cooling vents.
Supported Mounting Solutions The VESA mounting plate on the Invitium allows the use of standard mounting hardware. VESA FPMPMI-compliant mounting solutions are available through Planar Systems, Inc. Contact your Invitium vendor or visit the Planar web site. www.planar.com/medical/medicalworkstation.
Installing the Invitium Guidelines Operating • Operate within 32° to 104° Fahrenheit (0° (zero) to 40° Celsius) • Store within -4° to 149° Fahrenheit (-20° to 65° Celsius) • Allow proper ventilation for sufficient airflow and heat dissipation Mounting • Supports 23 lb • VESA-compatible, 75 mm or 100 mm pattern • Mounting hardware meets the Occupational Health and Safety Administration (OSHA), National Fire Protection Association (NFPA) 5
Precautions • Secure all electrical cables. Replacement cables are available from Planar. • Firmly grasp the Invitium with two hands and place it in its original packaging when moving it to a different location. Caution – Electrical and fire hazards • Install where the temperature range is 32° to 104° Fahrenheit (0° (zero) to 40° Celsius). Usage outside that range can damage the system. • Plug the Invitium into a grounded power outlet to safeguard the system from power surges.
Attach the Mounting Fixture Use four 4 mm 0.7 pitch stainless steel screws of the appropriate length for a tight fit. You need 4 mm of the screw’s threads engaged in the Invitium’s VESA plate for proper support. 1 Install the mounting fixture. (Refer to the vendor documentation.) 2 Attach the Invitium to the fixture using the VESA panel on the back of the Invitium.
3 Tighten the top two screws through the fixture’s mounting plate. 4 Insert and tighten the bottom two screws through the mounting plate.
Open the Clamshell 1 Tilt or rotate the Invitium away from the mounting fixture to allow the clamshell to open fully. Note Accessing the connector bay differs depending on the mounting fixture. 2 Loosen the screws on the portion of the clamshell located below the VESA mounting plate on the Invitium. 3 Open the clamshell.
Connect the Cables 1 Connect the keyboard, mouse, and other peripherals. Caution – Electrical hazard PC audio is connected through the video/audio cable. Do not disconnect the video/audio cable or connect another display to this port. Wireless PC card PC card slots 2 Power Video/ ports audio Microphone input COM ports Antenna 1 3 2 4 USB ports Ethernet PC audio Keyboard (line) input Install the PCMCIA wireless network card, if appropriate.
3 Connect the power adapter. Align the pins on the DC connector with the holes in the power port and push the connector until it locks into place. Caution – Hardware damage Do not force the connector into the power port. The pins may bend if they do not align with the holes. cl 4 ic k! Close the clamshell and fasten the screws. To disconnect the power adapter 1 Grasp the base of the DC connector and pull it back gently. 2 Keeping the base pulled back, tug the power adapter out.
1 2 I n vi t i u m O p e r a t i o n s Ma n u a l
Start the Invitium Press the power switch to the on (|) position.
Adjust the Display Brightness Display power Keyboard light Keyboard light Brightness Press the + or – control to adjust display brightness. Display power Press the display power button to toggle power on or off. Keyboard light Place the keyboard directly under the light. Press the keyboard light to brighten the keyboard during night use. The light turns off after 30 minutes.
Install Additional Software The Invitium comes with the Windows operating system and drivers installed. You can customize the system configuration by installing additional software. Tn4 Changes to the configuration are preserved on the flash disk. To assure compatibility, the software image can only be updated in its entirety. Certified combinations of drivers and applications are available. Contact your Invitium vendor or visit www.planar.com.
Index A about the system, 1–4 adapter, power, 2 additional software, installing, 14 adjusting the display, 13 antenna, 10 attaching cables, 9–11 mounting fixture, 7–8 B battery pack, 2 brightness, adjusting, 13 C carts, medical, 4 certifications, vi clamshell, opening, 9 cleaning solutions, ix cleaning the display, ix components, system, 1 configuration, 3 connecting the cables, 9–11 connector bay, 3, 10 conventions, documentation, viii cooling system, 3 D declaration of conformity, vi detaching the powe
M maintaining the display, ix manufacturer’s declaration electromagnetic emissions, vi electromagnetic immunity, vi medical carts, 2, 4 mounting fixture attaching, 7–8 guidelines, 5 supported, 4 mounting fixtures, 2 mouse, 2 N network card, 10 O on/off switch, 12 opening clamshell, 9 operating environment, 3 optional equipment, 2, 4 overview, 1–4 P PCMCIA card, 10 ports, 10 ports, system, 3 power adapter, 2 connecting, 11 detaching, 11 18 I n v i t i u m O p e ra t i o n s M a n u a l power button, di