User's Manual
FULL 
THE BREECH FULL TIME PARAMETER 
Tumbling paintballs can take time to settle in the 
breech before they can be successfully fired. This 
parameter is used to set the amount of time that a 
paintball has to be in the breech before the Ego9 is 
allowed to fire. This parameter can be set between 1.0 
and 20 milliseconds in 0.5ms increments. 
PULL TM 
THE TRIGGER PULL TIME PARAMETER 
The PULL TM parameter is used to set the minimum 
amount of time that the trigger must be pulled before 
it is recognised as a valid trigger pull. This parameter 
can be set between 3.0 and 20.0 milliseconds in 0.5 
increments.
REL TM 
THE TRIGGER RELEASE TIME PARAMETER 
The REL TM parameter is used to set the minimum 
amount of time that the trigger must be released 
before it is recognised as a valid trigger release. 
This parameter can be set between 3.0 and 25.0 
milliseconds in 0.1 millisecond increments. 
PULL PT 
THE TRIGGER PULL POINT PARAMETER 
The PULL PT parameter is only available if OPTO has 
been selected in the Hardware Menu. PULL PT defines 
the point at which the trigger is considered pulled and 
is adjustable between 51% and 99% in 1% increments.