Clean and check the condition of the single internal 
006 NBR90 o-ring in the front of the OOPS insert, replace 
if necessary SEE FIGURE 18.5. Lubricate all three of these 
o-rings liberally using Eclipse Grease SEE FIGURE 18.6.
Replace the OOPS insert into the OOPS body ensuring 
that the o-ring end goes in rst, pushing it into place SEE 
FIGURE 18.7
.
Lubricate the narrow end of the OOPS pin with a smear 
of Eclipse Grease and push the pin, narrow end rst, into 
the OOPS body so that it sits in the OOPS insert and pokes 
through the front of the OOPS body SEE FIGURE 18.8.
Screw the OOPS knob back onto the OOPS body until only 
a couple of threads are showing SEE FIGURE 18.9. 
Reconnect the macroline hose to the tting on the OOPS 
body SEE FIGURE 18.10.
You have now successfully cleaned and maintained your 
On/O purge system.
FIG 18.10FIG 18.9
FIG 18.8FIG 18.7
FIG 18.6
FIG 18.5
WARNING: IF YOU ARE AT ALL UNSURE OF PERFORMING 
THE MAINTENANCE PROCEDURE PLEASE CONTACT 
YOUR NEAREST ECLIPSE SERVICE CENTRE. SEE PAGES 
7273