Manual
VISIT WWW.PLANETECLIPSE.COM
ADVANCED SET-UP
20
VISIT WWW.PLANETECLIPSE.COM
THE FIRING MODE PARAMETER.
The Firing Mode Parameter is used to control the firing mode of the 
Etek2. The Firing Mode Parameter is displayed by a Red light on 
the Control Console when you are in the Set Up Menu. There are 
five selectable Firing Modes on the Etek2. Each of the selectable 
firing modes has its own features as outlined below:
SEMI 1
 (Mode 1 on the Firing Mode Parameter)
This is the default firing mode which produces one shot for every pull 
of the the trigger. This mode is uncapped with the Break Beam Sensor 
System (BBSS) enabled.
SEMI 2
 (Mode 2 on the Firing Mode Parameter)
This mode is the same as Semi 1 mode, except for the fact that 
the rate of fire is capped at the MAX ROF setting (bps).
RAMP 1
 (Mode 3 on the Firing Mode Parameter)
This mode allows the rate of fire to ramp to a maximum set by 
the Maximum Rate of Fire with BBSS enabled parameter, once 
the trigger has been pulled four times at a minimum rate of 5 
pps (pulls per second), and allows this rate of fire to maintained 
as long as the required trigger pull rate is maintained. After the 
last trigger pull, the ramp can be restarted with a single trigger 
pull if that pull occurs within one second.
RAMP 2
 (Mode 4 on the Firing Mode Parameter)
This mode is the same as Ramp 1 mode but without the one second 
ramp restart.
RAMP 3
 (Mode 5 on the Firing Mode Parameter)
This mode is the same as Ramp 2 mode but activates at a minimum rate 
of 7.5 pulls per second.
RAMP 4
 (Mode 6 on the Firing Mode Parameter)
This mode is the same as Ramp 1 but with a maximum rate of fire of
13bps. This mode is compliant with the 2008 PSP rules covering firing
modes,  provided  that  the  Maximum  ROF  parameter  remains 
unchanged.
RAMP 5
 (Mode 7 on the Firing Mode Parameter)
This mode is the same as Ramp 2 but with a maximum rate of fire of 
12bps
and a ramp activation point of 6.0 pulls per second. This mode is
compliant with the 2008 Millennium Series rules covering firing modes,
provided that the Maximum ROF parameter remains unchanged.
Please Note:  Certain modes may only be available in certain countries 
and on certain models of the Etek2s.
THE MAXIMUM RATE OF FIRE 
(CAPPED MODES).
 The Maximum Rate of Fire in capped modes is used to control 
how fast the Etek2 can cycle in each of the capped firing 
modes; Semi 2, Ramp 1, Ramp 2 and Ramp 3.
The Maximum Rate of Fire (capped modes) Parameter is 
displayed by a Green light on the Control Console when you 
are in the Set Up Menu. 
This is fully adjustable between 10.0 balls per second and 15.4 
balls per second in 0.1 bps increments.










