CLEANING THE INLINE 
REGULATOR
Disconnect the hosing from your Inline Regulator allowing it to be 
unscrewed from the Front Regulator Mount (FRM) (SEE FIGURE 5.7).
Turn  the  Inline  Regulator  upside  down  and  carefully  unscrew  the  two 
sections, taking care not to lose the spring from inside the regulator (SEE 
FIGURE 5.8).
By firmly gripping the exposed end of the aluminium  regulator  piston, 
carefully remove the piston and spring in its entirety (SEE FIGURE 5.9).
Insert a 1/8” hex key into the adjuster screw in the bottom half of the inline 
regulator, and wind the screw clockwise through the bottom section of 
the regulator body (SEE FIGURE 5.10) and pull free when it will no longer turn 
upwards anymore. 
WARNING: DE-GAS YOUR MARKER, DISCHARGING ANY STORED 
GAS  IN  A  SAFE DIRECTION,  AND  REMOVE  THE  BARREL  AND 
LOADER TO MAKE THE ETEK2 EASIER TO WORK ON. 
FIG 5.7
FIG 5.8
FIG 5.9
FIG 5.10
NOTE: THE ADJUSTER SCREW CAN ONLY BE REMOVED BY TURNING 
IT UPWARDS  THROUGH THE BOTTOM SECTION OF THE INLINE 
REGULATOR. THE REGULATOR WILL BECOME DAMAGED IT  THE 
ADJUSTER SCREW IS REMOVED INCORRECTLY.