Manual
THE SET UP MODE 
The SET UP MODE can only be entered if tournament lock is 
o. See page 25 for details on the tournament lock.
To activate the SET UP MODE, rstly ensure that the Etek3 
is switched o. Pull and hold the trigger, and whilst the 
trigger is still pulled push and hold the  button until 
the ‘E’ and the ‘O’ on the Navigation Console alternately 
ash white to indicate entry to SET UP MODE. When you 
have entered the SET UP MODE, the ‘G’ on the Navigation 
Console will turn red to indicate the rst parameter of the 
SET UP MODE. You can now release the trigger.
Press the  button to scroll through each of 
the parameters on the SET UP MODE:
To see the value that any setup parameter is set to, pull and 
release the trigger. the value will be indicated by ashing 
the tens on the ‘E’ LED, the units on the ‘G’ LED and tenths 
on the ‘O’ LED. E.g. 14.5 would be indicated as follows-
 1 FLASH OF THE ‘E’ LED
 4 FLASHES OF THE ‘G’ LED
 5 FLASHES OF THE ‘O’ LED 
A zero is indicated by no ashes. E.g. 3.0 would be 
indicated as follows:
 0 FLASHES OF THE ‘E’ LED
 3 FLASHES OF THE ‘G’ LED 
 0 FLASHES OF THE ‘O’ LED
MODIFYING A PARAMETER 
You can modify a parameter by using the following 
guidelines.
1.
 Ensure that you are in SET UP MODE.
2.
 Choose the parameter that you wish to modify by 
pressing until G turns to the parameter colour.
3.
 Pull and hold the trigger for 1 second. The ‘E’ LED will 
light up.
4.
 Set the tens digit by pressing the trigger once for each 
ten, the ‘E’ LED will ash with each trigger pull. DO NOT pull 
the trigger if the required digit is zero.
5.
 Push the  button. The ‘G’ LED on the Navigation 
Console is illuminated.
6.
 Set the units digit by pressing the trigger once for each 
unit, the ‘G’ LED will ash with each trigger pull. DO NOT 
pull the trigger if the required digit is zero.
7.
 Push the  button. The ‘O’ on the Navigation Console is 
illuminated.
8.
 Set the units digit by pressing the trigger once for each 
unit, the ‘O’ LED will ash with each trigger pull. DO NOT 
pull the trigger if the required digit is zero.
9. 
Push the button. The “E”, “G” and “O” will ash three 
times; if the colour is green then the value has been 
accepted and saved, if the value is red then the value has 
been rejected and restored to its value before modifying.
For example to set a parameter to 14.5 - 
 PULL THE TRIGGER 1 TIME WHILE THE ‘E’ LED IS LIT THEN 
PRESS
 PULL THE TRIGGER 4 TIMES WHILE THE ‘G’ LED IS LIT 
THEN PRESS
 PULL THE TRIGGER 5 TIMES WHILE THE ‘O’ LED IS LIT 
THEN PRESS
To leave a parameter unchanged having already started 
to modify it, simply set an illegal value (any single digit 
greater than 9) and the value will consequently be rejected. 
COLOUR
PARAMETER
RANGE
Red
Green
Blue
White
Dark Red
Purple
Light Blue
Yellow
Firing Mode
Maximum ROF with
BBSS on (for capped 
modes only).
Dwell
Debounce
Ball Detection Time
1 to 3
4.0 bps to 15.4 
bps
4.0 bps to 15.4 bps
5.0 pps to 10.0 pps
1.0 ms to 15.0 ms
0.0 to 1.0 s
1 to 10
1 ms to 10 ms
Maximum ROF with 
BBSS o.
Ramp Kick-in Rate 
(ramp only)
Ramp Restart Time 
(ramp only)
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR ETEK3
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
27.
ADVANCED SET-UP
ADVANCED SET-UP
QUICK GUIDE