Manual
SET UP PARAMETERS 
The rst ve set up parameters will need to be set to 
comply with the rules of the eld or site at which this Etek3 
is used. It is the user’s responsibility to ensure that these 
parameters are correctly set.
THE FIRING 
MODE 
PARAMETER
This parameter is used to control the 
ring mode of the Etek3. The FIRING 
MODE
 parameter is indicated by a red 
light on the Navigation Console when 
you are in the SET UP mode. There 
are three selectable FIRING MODES as 
outlined below:
1.0 : UNCAPPED SEMI
In this mode the Etek3 will re one shot for every pull of 
the trigger. This mode is uncapped with the BBSS enabled. 
If the BBSS is o then the rate of re is limited by the 
MAXIMUM ROF WITH BBSS OFF parameter.
2.0 : CAPPED SEMI
This mode is the same as the UNCAPPED SEMI mode, except 
that the rate of re is capped to the MAXIMUM ROF WITH 
BBSS ON
 parameter.
3.0 : CAPPED RAMP
This mode allows the rate of re to ramp to a maximum 
set by the MAXIMUM ROF WITH BBSS ON parameter, once 
the trigger is being pulled at the required pulls per second 
rate set by the RAMP KICKIN RATE parameter. The number of 
trigger pulls has to remain equal or above the RAMP KICKIN 
RATE 
parameter to continue ramping. After the last trigger 
pull, the ramp can be restarted with a single trigger pull 
within the time set in the RAMP RESTART TIME parameter.
Certain modes may only be available in certain countries 
and on certain models of the Etek3.
THE MAXIMUM 
ROF WITH BBSS 
ON
CAPPED MODES
 In capped ring modes this parameter 
is used to control how fast the Etek3 
can cycle. 
The MAXIMUM ROF WITH BBSS ON 
parameter is indicated by a green light on the Navigation 
Console when you are in the SET UP mode. 
This is fully adjustable between 4.0 balls per second and 
15.4 balls per second in 0.1 bps increments.
THE MAXIMUM 
ROF WITH BBSS 
OFF
This parameter is used to control 
how fast the Etek3 cycles when the 
Break Beam Sensor System has been 
disabled.
The MAXIMUM ROF WITH BBSS OFF 
parameter is indicated by a blue light on the Navigation 
Console when you are in the SET UP mode.
This parameter is fully adjustable between 4.0 balls per 
second and 15.4 balls per second in 0.1 bps increments.
This parameter should be set to match the slowest speed 
of the loading system in use.
28.
ADVANCED SET-UP