REMOVING AND 
ATTACHING THE FRAME 
Disconnect any hosing and unscrew the inline regulator 
from the front regulator mount as detailed in the Cleaning 
the Inline Regulator section of this maintenance guide 
(pages 56-57).
Using a 5/64” hex key remove the six screws that attach the 
Etek3 rubber grips to the Etek3 grip frame SEE FIGURE 
18.1
. Unplug the solenoid and unplug the break beam 
sensor system from their connections on the Etek3 circuit 
board SEE FIGURE 18.2.
Using a 1/8” hex key undo the two frame retaining screws 
SEE FIGURE 18.3 and remove the frame from the Etek3 
body, taking care not to damage any wires SEE FIGURE 
18.4
.
You have now removed the frame.
FIG 13.7
FIG 18.3
FIG 18.4
FIG 18.2
FIG 18.1
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY 
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE 
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS TO 
MAKE THE MARKER EASIER AND SAFER TO WORK ON.