THE SET UP MODE 
The Set Up Mode can only be entered if  tournament lock 
is off. See page 29 for details on the tournament lock.
To activate the Set Up Mode, firstly ensure that the Etek4 
is switched off. Pull and hold the trigger, and whilst the 
trigger is still pulled push and hold the 
 button until 
the ‘E’ and the ‘O’ on the navigation console alternately 
flash white to indicate entry to Set Up mode. When you 
have entered the Set Up mode, the ‘G’ on the navigation 
console will turn red to indicate the first parameter of  the 
Set Up Mode. You can now release the trigger. 
Press the 
 button to scroll through each of  
the parameters on the Set Up Mode:
To see the value that any setup parameter is set to, pull 
and release the trigger. The value will be indicated by 
flashing the tens on the ‘E’ LED, the units on the ‘G’ LED 
and tenths on the ‘O’ LED. E.g. 14.5 would be indicated 
as follows-
- 1 FLASH OF THE ‘E’ LED
- 4 FLASHES OF THE ‘G’ LED
- 5 FLASHES OF THE ‘O’ LED 
A zero is indicated by no flashes. E.g. 3.0 would be 
indicated as follows:
- 0 FLASHES OF THE ‘E’ LED
- 3 FLASHES OF THE ‘G’ LED 
- 0 FLASHES OF THE ‘O’ LED
MODIFYING A PARAMETER 
You can modify a parameter by using the following 
guidelines.
1. Ensure that you are in Set Up mode.
2. Choose the parameter that you wish to modify by 
pressing 
 until G turns to the parameter colour.
3. Pull and hold the trigger for 1 second. The ‘E’ LED will 
light up.
4. Set the tens digit by pressing the trigger once for each 
ten, the ‘E’ LED will flash with each trigger pull. DO NOT 
pull the trigger if  the required digit is zero.
5. Push the 
 button. The ‘G’ LED on the navigation 
console is illuminated.
6. Set the units digit by pressing the trigger once for each 
unit, the ‘G’ LED will flash with each trigger pull. DO NOT 
pull the trigger if  the required digit is zero.
7. Push the   button. The ‘O’ on the navigation console 
is illuminated.
8. Set the units digit by pressing the trigger once for each 
unit, the ‘O’ LED will flash with each trigger pull. DO NOT 
pull the trigger if  the required digit is zero.
9. Push the   button. The “E”, “G” and “O” will flash 
three times; if  the colour is green then the value has been 
accepted and saved, if  the value is red then the value has 
been rejected and restored to its value before modifying.
For example to set a parameter to 14.5 - 
- PULL THE TRIGGER 1 TIME WHILE THE ‘E’ LED IS LIT 
THEN PRESS 
- PULL THE TRIGGER 4 TIMES WHILE THE ‘G’ LED IS LIT 
THEN PRESS 
- PULL THE TRIGGER 5 TIMES WHILE THE ‘O’ LED IS LIT 
THEN PRESS 
To leave a parameter unchanged having already started 
to modify it, simply set an illegal value (any single 
digit greater than 9) and the value will consequently be 
rejected. 
COLOUR
PARAMETER
RANGE
Red
Green
Blue
White
Dark Red
Purple
Light Blue
Yellow
Firing Mode
Maximum ROF with 
BBSS on (capped 
modes only).
Dwell
Debounce
Ball Detection Time
1 to 3
4.0 bps to 15.4 
bps
4.0 bps to 15.4 
bps
5.0 pps to 10.0 
pps
1.0 ms to 15.0 ms
0.0 to 1.0 s
1 to 10
1 ms to 10 ms
Maximum ROF 
with BBSS off.
Ramp Kick-in Rate 
(ramp only)
Ramp Restart 
Time (ramp only)
CONTENTS
ORIENTATION
QUICK SET-UP
USING THE ETEK4
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES
INDEX
31.
ADVANCED SET-UP
QUICK GUIDE