Manual
The remaining set up parameters are used to 
configure the performance of  the Etek4.
DWELL
The Dwell parameter controls the 
amount of  time that the solenoid 
is energised and therefore the 
amount of  gas that is released 
with each shot.
The Dwell parameter is indicated 
by a purple light on the navigation 
console when you are in the Set 
Up mode.
This parameter is fully adjustable between 1.0ms and 
15.0ms in 0.1ms increments.
DEBOUNCE
The Debounce parameter is used 
to set the level of  Debounce (anti 
trigger bounce) on your Etek4.
The Debounce parameter is 
indicated by a ‘light blue’ light on 
the navigation console when you 
are in the Set Up mode.
This parameter is fully adjustable 
between Debounce 1 and Debounce 9 with a higher 
value reducing the amount of trigger bounce.
THE BALL 
DETECTION TIME
The Ball Detection Time parameter 
defines how long a paintball has 
to sit in the breech of the Etek4 
before it is considered ready to fire.
The Ball Detection Time parameter 
is indicated by a yellow light on the 
navigation console when you are in 
the Set Up mode. 
This parameter is fully adjustable between 1 ms and 
10 ms in 1 ms increments.
THE RESET PARAMETER
 Whilst in Set Up Mode, it is 
possible to reset all of the control 
parameters to the factory default 
settings in the following way: 
1. Push and hold the Lock button 
for two seconds.
2. The “E”, “G” and “O” on the 
navigation console will repeatedly 
flash blue to indicate that the 
factory default settings have been 
restored.
34.