Manual
LOCK
THE TOURNAMENT LOCK PARAMETER
The Etek4 has a tournament lock which 
prevents the user from making changes 
to any parameter that affects the way in 
which the Etek4 shoots without the use of  
tools.
This parameter is used to set the state of  
the tournament lock and has the following 
choices:-
> ON:
 Turn on the tournament lock. 
The Set-Up Menu is only accessible by 
removing the right hand cheek of  the rubber grips and 
then pressing and holding the red SETUP button on 
the circuit board. 
> OFF:
 Turn off  the tournament lock. The Set-Up 
Menu is added to the Main Menu, making it easily 
accessible by pressing and holding the 
 button.
> CANCEL: Cancel selection and leave the parameter 
unchanged.
1
All presets are correct at time of printing. Please check with the 
event organiser to make sure the above presets are still considered 
legal.
2
The current preset configuration can be viewed from the run screen 
by pressing the   button. 
3
Certain modes may only be available in certain countries and on 
certain models of the Etek4.
PRESET
THE PRESET MENU
In order to simplify the set up of  the Etek4 a number 
of  Preset configurations are available for selection. 
Choosing one of  these presets will cause all of  the 
necessary parameters to be set in such a way as to 
make the Etek4 comply with the rules governing a 
particular paintball league. It is also possible for the 
user to save up to two Preset configurations of their 
own.
1,2,3
LOAD 
THE LOAD PRESET PARAMETER 
This parameter is used to load the 
required preset configuration and has the 
following choices:
> USER 1: Load a set of  custom firing mode 
parameters that have been previously 
saved by the user.
> USER 2: Load a set of  custom firing mode 
parameters that have been previously 
saved by the user.
> FACTORY: Reset every parameter to the 
factory set default. The Etek4 leaves the 
factory set in this way.
> NPPL: Load a set of  parameters that configures the 
Etek4 to comply with the 2008 NPPL rules governing 
firing modes.
1
> PSP 10: Load a set of  parameters that configures the 
Etek4 to comply with the PSP rules governing firing 
modes in lower divisions (10bps).
1
> PSP 12: Load a set of  parameters that configures the 
Etek4 to comply with the PSP rules governing firing 
modes in higher divisions (12bps).
1
> MS10: Load a set of  parameters that configures the 
Etek4 to comply with the 2009 Millennium Series 
rules governing firing modes.
1
> CANCEL: Editing is cancelled and the parameter 
remains unchanged. 
CONTENTS
ORIENTATION
QUICK SET-UP
USING THE ETEK4
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES
INDEX
47.
EMORTAL BOARD
QUICK GUIDE