THE FILTER MENU 
The parameters on the Filter Menu are all used to tune 
the Etek4’s software filters which prevent the Etek4 
from firing unless all of  the necessary conditions are 
met. The factory default settings will be suitable for 
most set-ups, however certain loader and trigger set-
ups may require modification 
of  one or more of  these parameters: 
DBOUNCE 
THE DEBOUNCE PARAMETER 
The Dbounce parameter is used to combat 
any trigger bounce that might occur in the 
Etek4 and can be set between level 1 and 
level 9 in one level increments.
> LEVEL 9: Level 9 providing the most 
filtering. 
   LEVEL 8 - LEVEL 2     
> LEVEL1: Level 1 providing the least 
filtering. 
> CANCEL: Cancel editing and leave the 
parameter unchanged. 
EMPTY 
THE EMPTY BREECH TIME PARAMETER 
In order for the BBSS to function correctly it 
must first detect that the bolt is fully retracted 
and the breech is empty, and then detect that 
a paintball is loaded into the breech before the 
Etek4 is allowed to fire. Slots or holes in some 
third party bolts can fool the BBSS and so this 
parameter is used to specify a minimum time 
that the breech must be empty. The parameter 
can be set between 1.0 and 20.0ms in 0.5ms 
increments.
FULL 
THE FULL PARAMETER 
Tumbling paintballs can take time to 
settle in the breech before they can be 
successfully fired. This parameter is used 
to set the amount of  time that a paintball 
has to be in the breech before the Etek4 is 
allowed to fire. This parameter can be set 
between 1.0 and 20 milliseconds in 0.5ms 
increments. 
PULL TM 
THE PULL TIME PARAMETER 
The PULL TM parameter is used to set the 
minimum amount of  time that the trigger 
must be pulled before it is recognised as 
a valid trigger pull. This parameter can be 
set between 3.0 and 25.0 milliseconds in 
0.5 ms increments.
REL TM 
THE RELEASE TIME PARAMETER 
The REL TM parameter is used to set the 
minimum amount of  time that the trigger 
must be released before it is recognised as 
a valid trigger release. This parameter can 
be set between 3.0 and 25.0 milliseconds 
in 0.5 ms increments. 