THE SL3 INLINE REGULATOR
Disconnect the macroline hosing from your inline 
regulator by pulling back the collet section of the 
hose fitting and keeping the collet depressed. Pull the 
macroline hose out of  the hose fitting and release the 
collet. 
Unscrew the inline regulator from the Etek4 body in 
a counter-clockwise direction 
(SEE FIGURE 17A). 
Inspect the o-ring at the top of  the threads on the 
Etek4 body for damage. Replace and re-lubricate as 
necessary
1
.
Turn the inline regulator upside down and carefully 
unscrew the bottom section from the top section 
(SEE FIGURE 17B). 
Push both the piston and spring out of  the top of  the 
inline regulator 
(SEE FIGURE 17C). 
Insert a 1/8” hex key into the adjuster screw in 
the bottom section of  the inline regulator, turn the 
adjuster screw clockwise through the top of  the inline 
regulator bottom 
(SEE FIGURE 17D), and pull out 
of  the inline regulator bottom when it will no longer 
turn upwards
2
.
Thoroughly clean the 011 NBR70 o-rings that sit on 
the outside of  the adjuster assembly, then re-lubricate 
with Eclipse Grease 
(SEE OVERLEAF FIGURE 
17E)
1
. 
1
If any o-rings are damaged please replace them. Extra o-rings 
are available from planeteclipse.com or your local Eclipse Service 
Centre. 
2
The adjuster screw can only be removed by turning it upwards 
through the bottom section of the inline regulator. The regulator 
may be damaged if the adjuster screw is removed incorrectly.
DE-GAS YOUR MARKER, DISCHARGING ANY 
STORED GAS IN A SAFE DIRECTION, AND REMOVE 
THE BARREL, LOADER, AIR SYSTEM AND ANY 
PAINTBALLS TO MAKE THE MARKER EASIER AND 
SAFER TO WORK ON.