REMOVING AND ATTACHING 
THE FRAME 
Disconnect any hosing and unscrew the inline 
regulator from the front regulator mount as detailed 
in the Cleaning the Inline Regulator section of  this 
maintenance guide (pages 56-57).
Using a 5/64” hex key remove the six screws that 
attach the Etek4 rubber grips to the Etek4 grip frame 
(SEE FIGURE 22A). Unplug the solenoid 
A
 and 
break beam sensor system connectors 
B
 from the 
Etek4 circuit board 
(SEE FIGURE 22B).
Using a 1/8” hex key undo the two frame retaining 
screws 
(SEE FIGURE 22C) and remove the frame 
from the Etek4 body, taking care not to damage any 
wires 
(SEE FIGURE 22D).
You have now removed the frame.
DE-GAS YOUR MARKER, DISCHARGING ANY 
STORED GAS IN A SAFE DIRECTION, AND REMOVE 
THE BARREL, LOADER, AIR SYSTEM AND ANY 
PAINTBALLS TO MAKE THE MARKER EASIER AND 
SAFER TO WORK ON.
WARNING
FIG 22A
FIG 22b
FIG 22C
FIG 22D
A
B
64.
mAINTENANCE