Manual
THE ETEK4 TRIGGER 
ASSEMBLY
Having removed the trigger frame completely from the 
Etek4 body (see page 64), remove the retaining clip 
that holds the bearing carrier in place in the top of  
the frame, this is best done using some pointed nose 
pliers to pinch the clip and lift free from the frame 
(SEE FIGURE 23A). 
Gently lift the bearing carrier and trigger assembly 
free from the frame taking care not to damage the 
micro-switch 
(SEE FIGURE 23B).
Using a 1/16” hex key, loosen the trigger pin retaining 
set screw in the back of the trigger 
(SEE FIGURE 
23C)
. Use a small hex key to push the trigger pin out 
of  the bearing carrier from one side 
(SEE FIGURE 
23D)
.
Clean the trigger and bearing carrier thoroughly and 
also clean the space within the frame that the trigger 
sits into.
DE-GAS YOUR MARKER, DISCHARGING ANY 
STORED GAS IN A SAFE DIRECTION, AND REMOVE 
THE BARREL, LOADER, AIR SYSTEM AND ANY 
PAINTBALLS TO MAKE THE MARKER EASIER AND 
SAFER TO WORK ON.
WARNING
FIG 23b
FIG 23A
FIG 23D
FIG 23C
66.