Manual
WARNING!
De-gas your marker, discharging any stored gas in a safe direction, and 
remove the barrel, loader, air system and any paintballs to make the marker 
easier and safer to work on.
WARNING
USING THE ETEK
6 ETEK5 MANUAL
FACTORY SET-UP GUIDE
Before using the ETEK5 it is important to make sure that the inline regulator, low 
pressure regulator and all electronically controlled parameters are set correctly, 
as some of these may have a negative (and potentially damaging) effect on the 
marker (in terms of performance and reliability), if incorrectly set.
The steps below will restore the ETEK5 to the state that it left the factory.
Reset the control parameters to the factory settings (see page 28).
Check the inline regulator adjuster screw is set to 4 turns clockwise from its 
maximum output (counter-clockwise) position (see gure 1A). This will ensure the 
inline regulator is set to an output pressure that will not damage the ETEK5 when 
supplied with compressed air/nitrogen (see page 21 for more information on the 
inline regulator).
Check the low pressure regulator adjuster screw is set to one turn anti-clockwise 
from its fully inwards position (see gure 1B) (see page 21 for more information 
on the low pressure regulator).
How to get up and running
quickly with your ETEK5.
FIG 1A
FIG 1B
+
+
_
_