Manual
Set up pArAMeterS 
The first three set up parameters will need to be set 
to comply with the rules of  the field or site at which 
this Etha is used. It is the user’s responsibility to 
ensure that these parameters are correctly set.
the firinG Mode 
pArAMeter
This parameter is used to control 
the firing mode of  the Etha. The 
firing mode parameter is indicated 
by a red light on the navigation 
console when you are in the set up 
mode. There are four selectable 
firing modes as outlined below:
1 : UNCAPPED SEMI
In this mode the Etha will fire one 
shot for every pull of  the trigger. 
This mode is uncapped with the 
BBSS enabled. If  the BBSS is off  
then the rate of  fire is limited by 
the Maximum ROF with BBSS Off 
parameter.
2 : CAPPED SEMI
This mode is the same as the Uncapped Semi mode, 
except that the rate of fire (ROF) is determined by the 
maximum ROF parameters (BBSS On and BBSS Off).
3 : PSP 2011 COMPLIANT RAMPING
This mode allows the marker to fire in a ramping 
mode as specified in the 2011 PSP Series rules.
4 : 
MILLENNIUM 2010 COMPLIANT RAMPING
This mode allows the marker to fire in a ramping 
mode as specified by the 2010 Millennium Series 
rules.
Certain modes may only be available in certain 
countries and on certain models of  the Etha. 
the MAXiMuM rof 
With bbSS on
(cApped ModeS)
In capped firing modes this 
parameter is used to control how 
fast the Etha can cycle. 
The Maximum ROF with BBSS On 
parameter is indicated by a green 
light on the navigation console when 
you are in the set up mode. 
This is fully adjustable between 4.0 
balls per second and 15.0 balls per 
second in 0.1 bps increments.
the MAXiMuM rof With 
bbSS off
This parameter is used to control 
how fast the Etha cycles when the 
Break Beam Sensor System has been 
disabled.
The Maximum ROF with BBSS Off 
parameter is indicated by a blue 
light on the navigation console when 
you are in the set up mode.
This parameter is fully adjustable 
between 4.0 balls per second and 
15.0 balls per second in 0.1 bps 
increments.
This parameter should be set to 
match the slowest speed of the 
loading system in use.
The Etha software parameters and presets are correct at time of printing. However newer versions of the Etha software may have different 
parameters and presets to those printed above. Some parameters may have ben added or removed entirely. Please contact your nearest 
service centre if you have any queries regarding the Etha software installed in your marker.
uSER INTERFACE