Manual
16
ETHA2
ELECTRONICS
THE SET-UP MODE
To modify the ETHA2 control parameters you must rst enter the  
set-up mode:
1
Fully depress and hold the trigger.
2
Switch on the ETHA2.
3
The status indicator should ash WHITE.
4
Release the trigger.
 If  the  status indicator ashes RED then access to set-up is denied 
because the tournament lock is still on. Turn o the tournament lock 
(page 31) and try again.
Once in set-up mode, use the trigger to cycle through the parameters, 
indicated by the colour of the status indicator (see table below). Quickly 
press the On/O button to display the current parameter value.
LED COLOUR PARAMETER RANGE
RED Preset 1 to 4
GREEN
Maximum ROF with BS on 
(capped modes only)
4.0 to 15.0 bps
BLUE Maximum ROF with BS off 4.0 to 15.0 bps
PURPLE Dwell 18 to 28
LIGHT BLUE Debounce 1 to 10
A long LED ash indicates the unit, whilst a short LED ash indicates the 
tenth. E.g., 5 long ashes and 3 short ashes would indicate 5.3.
Modifying a parameter:
1
Enter the set-up mode.
2
Select a parameter using the trigger.
3
Push and hold On/O button for 1 second to select.
4
The LED will go o.
5
Increase the unit value using the trigger, one pull per unit.
1
6
Push the On/O button to switch to tenths values.
2
7
Increase the tenths value using the trigger, one pull per tenth. 
Do not pull the trigger if the value should be 0.
8
 Push  the  On/O button to conrm. The status indicator will 
ash 3 times: GREEN if the value is accepted, RED if the value is 
invalid. If the status indicator was red then try again.
9
 Push and hold the On/O button until the status indicator turns 
BLUE to exit set-up mode.
To reset all of the parameters to their factory-set default values press 
and hold the tournament lock button for 2 seconds while in set-up 
mode. The status indicator will ash BLUE when the parameters have 
been reset.
1   The settings will return to their previous saved values if you do not 
pull the trigger for 5 seconds.
2  If a parameter does not support tenths, this will be skipped.