Manual
DEBOUNCE 
THE DEBOUNCE PARAMETER 
The DEBOUNCE parameter is used to combat 
any trigger bounce that might occur in the 
Geo2 and can be set between level 1 and 
level 9 in one level increments.
> LEVEL 9:
 Level 9 providing the most 
ltering (least ‘bouncy’).
> LEVEL1:
 Level 1 providing the least 
ltering (most ‘bouncy’).
> CANCEL:
 Cancel editing and leave the parameter 
unchanged.
EMPTY 
THE BREECH EMPTY TIME 
PARAMETER 
In order for the BBSS to function correctly 
it must rst detect that the bolt is fully 
retracted and the breech is empty, and then 
detect that a paintball is loaded into the 
breech before the Geo2 is allowed to re. 
The parameter can be set between 1.0 and 
20.0ms in 0.5ms increments. 
FULL 
THE BREECH FULL TIME PARAMETER 
Tumbling paintballs can take time to 
settle in the breech before they can be 
successfully red. This parameter is used 
to set the amount of time that a paintball 
has to be in the breech before the Geo2 is 
allowed to re. This parameter can be set 
between 1.0 and 20 milliseconds in 0.5ms 
increments. 
PULL TM 
THE TRIGGER PULL TIME PARAMETER 
The PULL TM parameter is used to set the 
minimum amount of time that the trigger 
must be pulled before it is recognised as a 
valid trigger pull. This parameter can be set 
between 3.0 and 20.0 milliseconds in 0.5 
increments.
RELEASE TM 
THE TRIGGER RELEASE TIME 
PARAMETER 
The RELEASE TM parameter is used to set the 
minimum amount of time that the trigger 
must be released before it is recognised as a 
valid trigger release. This parameter can be 
set between 3.0 and 25.0 milliseconds in 0.1 
millisecond increments.
PULL PT 
THE TRIGGER PULL POINT 
PARAMETER 
The PULL PT parameter is only available if 
OPTO has been selected in the HARDWARE 
menu. PULL PT denes the point at which 
the trigger is considered pulled and is 
adjustable between 51% and 99% in 1% 
increments.
RELEASE PT 
THE TRIGGER RELEASE POINT 
PARAMETER
The RELEASE PT parameter is only available 
if OPTO has been selected in the HARDWARE 
menu. RELEASE PT denes the point at which 
the trigger is considered released and is 
adjustable between 1% and 49% in 1% 
increments.