Manual
THE BREAK BEAM SENSOR 
SYSTEM INDICATOR BBSS 
The BBSS is able to switch itself o in the event of a 
blockage or contamination preventing it from functioning 
correctly. In this instance, the BBSS will switch itself back on 
once the blockage is cleared and the correct operation can 
be resumed.
The BBSS indicator on the main screen is used to indicate 
the eight possible states of the BBSS as follows:
THE AUX OUT INDICATOR 
The auxiliary socket on the Geo2 circuit board allows third 
party products such as loaders or RF transmitters to be 
interfaced to the Geo2. 
The AUX out indicator is turned on and o via the AUX OUT 
parameter (see page 42).
There are two possible conditions that can be indicated:
BBSS ENABLED AND BALL DETECTED
The Geo2 can be red at the maximum rate of 
re determined by the chosen ring mode.
BBSS FAULT HAS BEEN CLEARED AND 
BALL DETECTED
The sensor has been re-enabled. A ball is 
detected and the Geo2 can be red at the 
maximum rate of re determined by the 
chosen ring mode.
BBSS ENABLED NO BALL DETECTED
The Geo2 cannot be red.
BBSS FAULT HAS BEEN CLEARED AND 
NO BALL DETECTED
The sensor is enabled. No ball is detected so 
the Geo2 cannot be red. To reset the BBSS 
icon, use the  button to switch o the 
BBSS and then back on again.
BBSS DISABLED
The Geo2 can be red at a maximum rate of 
re as set by the BS OFF ROF
parameter (see 
page 35).
BBSS ENABLED IN TRAINING MODE
The BBSS has been over-ridden as the user 
has selected training mode. As the user has 
chosen to leave the BBSS on, the achievable 
rate of re is limited by the ring mode.
BBSS FAULT DETECTED
The system is disabled. The Geo2 can only 
be red at a maximum rate of 2bps less than 
the maximum rate of re, up to a maximum 
of 10 bps.
BBSS DISABLED IN TRAINING MODE
The BBSS has been over-ridden as the user 
has selected training mode. As the user has 
chosen to turn the BBSS o, the achievable 
rate of re is limited by the BS OFF ROF 
parameter (see page 35).
AUX OUT ENABLED 
The AUX OUT is enabled. Each time the circuit 
board detects a valid trigger pull a signal will 
be sent to the AUX connector on the circuit 
board.
AUX OUT DISABLED
The AUX OUT is disabled. No signal will be sent 
to the AUX connector on the circuit board.
24.