Quick Guide
10
5. Starting Web Management
The following shows how to start up the Web Management of the GEPON
OLT. To congure the Web system, connect a UTP cable to an Ethernet port on
a workstation and to the management port of the GEPON OLT. Note the OLT is
congured through an Ethernet connection. Please make sure the manager PC
must be set to the same IP subnet address.
For example, the default IP address of the OLT is 192.168.8.100, then the
manager PC should be set to 192.168.8.x (where x is a number between 1 and
254,except100),andthedefaultsubnetmaskis255.255.255.0.
EPL-2220
GEPON OLT
IP Address:
192.168.8.100
PC / Workstation
IP Address:
192.168.8.x
Management Port
RJ45/UTP Cable
Figure 5-1: IP Management Diagram
Logging in the GEPON OLT
1.Use Internet Explorer 8.0 or above Web browser and enter IP address
http://192.168.8.100(thefactorydefault IPaddressortheonethatyouhave
changedinconsole)toaccesstheWebinterface.
2.When the following dialog box appears, please enter the default user name and
password “admin” (or the password you have changed via console). The login
screeninFigure5-2appears.
DefaultUsername:admin
DefaultPassword:admin
Figure 5-2: Login Screen