0/100Base-TX to 100Base-FX Redundant Media Converter FT-1105A / FT-1205A User’s Manual
Trademarks Copyright © PLANET Technology Corp. 2007. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.
Revision PLANET Fast Ethernet Redundant Media Converter User’s Manual FOR MODELS: FT-1105A / FT-1205A Revision: 1.1 (November, 2007) Part No.
Table of Contents Chapter 1 OVERVIEW............................................................. 6 Chapter 2 PRODUCT FEATURES............................................... 8 Chapter 3 CHECKLIST.......................................................... 10 Chapter 4 PRODUCT OUTLOOK............................................. 11 Chapter 5 DIP SWITCH........................................................ 12 Chapter 6 INSTALLING THE CONVERTER .............................. 14 6.1 Stand-alone Installation....
Chapter 1 OVERVIEW Thank you for choosing the Smart 10/100Base-TX to 100BaseFX Media Converter, The Media Converter introduced here provides one channel media conversion between 10/100Base-TX and 100Base-FX. About the Redundant Media Converter The FT-1105A and FT-1205A are 3-Port Redundant Media Converters which support conversion between 10/100BaseTX and 100Base-FX network.
network. The SFP slot supports single-mode, multi-mode and WDM small-form factory type transceiver modules for your needs. With 100Base-FX SFP ports, the FT-1105A and FT-1205A are with high reliability and flexibility to extend the distance up to 2Km, 20Km, or longer. It depends on the 100Base-FX SFP transceiver modules. Ethernet signal that allows two type segments connect easily, efficiently and inexpensively.
Chapter 2 PRODUCT FEATURES Standard • Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX • IEEE 802.3x Full-Duplex Flow-Control, Back-Pressure in HalfDuplex eliminate packets loss Interface • FT-1105A: Dual 10/100Base-TX Copper, One 100Base-FX SFP Fiber optic ● FT-1205A: Dual 100Base-FX 10/100Base-TX Copper ● Auto-Negotiation Duplex for SFP 10/100Base-TX Fiber optic, Half-Duplex or One Full- ● Supports Auto MDI/MDI-X function ● Supports Maximum frame size up to 2046Kbytes.
● DIP Switch for 3-Port operation with Fast Ethernet switch mode or Redundant mode ● DIP switch for LPR (Loop back Reply) on / off selection ● Compact size, easy installation ● Co-work with PLANET 700/1000R/1500) MC family Media Chassis (MC-
Chapter 3 CHECKLIST Your FT-1105A / FT-1205A carton should contain the following items: The Redundant Fast Ethernet Converter AC-DC Power Adapter (Output: 5VDC, 2A max.) This user’s manual If any item is missing or damaged, please consult the dealer from whom you purchased your Redundant Fast Ethernet Converter. Note 10 FT-1105A / FT-1205A is with one vacant SFP module slot.
Chapter 4 PRODUCT OUTLOOK FT-1105A Front Panel ● Port-1 100Base SFP slot ● Port-2 TP connector (Primary Port) ● Port-3 TP connector (Backup Port) FT-1205A Front Panel ● Port-1 100Base SFP slot (Primary Port) ● Port-2 100Base SFP slot (Backup Port) ● Port-3 TP connector FT-1105A / FT-1205A Rear Panel One DC jack for DC power input and DIP switch to set 3-Port switch mode / 2-Port Redundant and Loop back reply Enable/ Disable function.
Chapter 5 DIP SWITCH There is a DIP switch for the setting on converter mode of copper and fiber port. Refer to the table below for more details. FT-1105A Switch 1 Switch 2 On 2-Port Redundant (TP) Off 3-Port Switch (default) On LBR ON Off LBR OFF (default) 2-Port Redundant (FT-1105A) When TP Redundancy is enabled, TP Port-2 and TP Port-3 are configured as either forwarding or disabled. At any given time, one port will be disabled and one port will be forwarding.
FT-1205A Switch 1 Switch 2 On 2-Port Redundant (Fiber) Off 3-Port Switch (default) On LBR ON Off LBR OFF (default) 2-Port Redundant (FT-1205A) When Fiber Redundancy is enabled, Fiber Port-1 (1) and Fiber Port-2 (2) are configured as either forwarding or disabled. At any given time, one port will be disabled and one port will be forwarding. 3-Port Switch When Fiber Redundancy is disabled, all ports (Port-1, Port-2 and Port-3) act as normal bridging ports.
Chapter 6 INSTALLING THE CONVERTER 6.1 Stand-alone Installation FT-1105A / FT-1205A is with high reliability and flexibility to extend the distance up to 2Km, 20Km, or longer. It depends on the 100Base-FX SFP transceiver modules. The SFP transceivers are hot-pluggable and hot-swappable. You can plug-in and out the transceiver to/from any SFP port without having to power down the converter.
Note It recommends using PLANET MFB-FX series 100Base-FX SFP on the converter. If you insert a SFP transceiver that is not supported, the converter will not recognize it. Step 4: Connect the fiber cable. Attach the duplex LC connector on the network cable into the SFP transceiver. Step 5: Attach fiber cable from the FT-1105A/FT-1205A to the fiber network. TX, RX must be paired at both ends. Step 6: Connect the 5VDC power adapter to the FT-1105A/FT1205A and verify that the Power LED lights up.
Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis. Figure 2-1: Insert a media converter into an available slot Step 3: Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package. Step 4: After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as shown in Figure 2-2. Step 5: Proceed with the steps 4 and steps 5 of session 6.
Chapter 7 Redundancy The FT-1105A / FT-1205A provide less than 10ms link redundancy for highly critical Ethernet applications. The redundant-mode supports auto-recover function. If the destination port of a packet is link down, it forwards the packet to the other port of the backup pair. The following figure shows the redundant function.
Chapter 8 Loop Back Reply The FT-1105A / FT-1205A supports auto loop back reply while receive loop back test packets on fiber port. Enable this function to tell the converter to reply fiber signals request from Web Smart media converter, such as PLANET FT-90x. You can use this to check whether the converter can communicate with partner converter. Please refer to the following figure. Note 18 For FT-1105A only, while enable the Loop Back Reply function, the Port-2 (TP) must be link up.
Chapter 9 LED INDICATORS The LED indicators give you instant feedback on status of the converter: System LED Color Function PWR Green Lit: Power on. FT-1105A / FT-1205A -10/100Base-TX Port LED LNK/ ACT 100 Color Green Function Lit: Indicate that the port is link up. Blink: Indicate that the converter is actively sending or receiving data over that port. Off: Indicate that the port is link down. Lit: Indicate that the port is operating at 100Mbps.
LED LNK/ ACT FDX/ COL Color Green Function Lit: Indicate that the port is link up. Blink: Indicate that the converter is actively sending or receiving data over that port. Off: Indicate that the port is link down. Lit: Indicate that the connection made through the corresponding port is running in Full-Duplex mode. Off: Indicate that the connection made through the corresponding port is running in Half-Duplex mode.
Chapter 10 PRODUCT SPECIFICATION Model Ports FT-1105A FT-1205A Copper 2 x 10/100Base-TX port 1 x 10/100Base-TX port Fiber 1 x 100Base-FX port 2 x 100Base-FX port Optic Interface SFP SFP Redundant Link Port 2 (Primary) Port 3 (Backup) Port 1 (Primary) Port 2 (Backup) Twistedpair Cable Speed 10Base-T : 2-Pair UTP Cat. 3,4,5, up to 100 m 100Base-TX : 2-Pair UTP Cat. 5, 5e up to 100 m ● 50/125μm or 62.5/125μm multi-mode fiber cable, Fiber-optic up to 2km.
APPENDIX A A.1 Device's RJ-45 Pin Assignments 10/100Mbps, 10/100Base-TX Contact MDI MDI-X 1 1 (TX +) 3 2 2 (TX -) 6 3 3 (RX +) 1 6 6 (RX -) 2 4, 5, 7, 8 Not used Not used Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. A.
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Figure A-1: Straight-Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network. A.
A.4 Power Information The power jack of FT-1105A / FT-1205A is with 2.5mm in the central post and required +5VDC power input. It will conform to the bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power connection, please contact your local sales representative. Please keep the AC-DC adapter as spare parts when your FT-1105A / FT-1205A is install in to a Media Chassis. 2.5mm DC Receptacle 2.5mm +5V for each slot DC receptacle is 2.