Users Manual of GPL-8000
ifid means the ID of the interface.
3. rmon collection
history index
[buckets
bucket-number]
[interval second]
[owner owner-name]
Enable the history function on the port.
index means the index of the history item.
Among all data collected by history item, the latest
bucket-number items need to be saved. You can
browse the history item of the Ethernet to abtain
these statistics values. The default value is 50 items.
second means the interval to abtain the statistics
data every other time. The default value is 1800
seconds.
owner string is used to describe some information
about the history item.
4. exit Enter the global office mode again.
5. exit Enter the management mode again.
6. write Save the configuration.
After a rMon history item is added, the device will obtain statistics values from the specified port every second
seconds. The statistics value will be added to the history item as a piece of information. If you run rmon
collection history index many times to configure history items with the same index, only the last
configuration is effective. You can run no rmon history index to cancel history items whose indexes are
index.
Too many system sources will be occupied; in the case. the value of
bucket-number is too big or the value of interval second is too small.