User's Manual
Table Of Contents
User’s Manual of IGS-2x00T Serial Device Server Series
16
■ Fast TP interface
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
■ Serial Interface
Supports RS-232, RS-422, RS-485 2-wire and RS485 4-wire.
2.1.2 Front Panel
The bottom panels of the Industrial Serial Servers are shown in Figure 2-1-2.
Bottom Panel
ICS-2200T ICS-2400T
Figure 2-1-2: Bottom Panels of Industrial Serial Servers
■ Reset button
On the bottom panel, the reset button is designed for rebooting the system and stopping the buzzer. The following is the
summary table of the reset button functions:
Reset Button
Reset Button Pressed and
Released
Function
System Reset
< 5 sec: System reboot Reboot the Industrial Serial Server
> 5 sec: Factory default
Reset the Industrial Serial Server to Factory
Default configuration. The Industrial Serial
Server will then reboot and load the default
settings as shown below:
。 Default Username: admin
。 Default Password: admin
。 Default IP address: 192.168.0.100
。 Subnet mask: 255.255.255.0
。 Default Gateway:
192.168.0.254
Buzzer Reset >1 sec Stop the buzzer