Fast TP interface
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
Serial Interface
Supports RS-232, RS-422, RS-485 2-wire and RS485 4-wire.
2.1.2 Front Panel
The bottom panels of the Industrial Serial Servers are shown in Figure 2-1-2.
Bottom Panel
ICS-2200T ICS-2400T
Figure 2-1-2: Bottom Panels of Industrial Serial Servers
Reset button
On the bottom panel, the reset button is designed for rebooting the system and stopping the buzzer. The following is the
summary table of the reset button functions:
Reset Button
Reset Button Pressed and
Released
Function
System Reset
< 5 sec: System reboot Reboot the Industrial Serial Server
> 5 sec: Factory default
Reset the Industrial Serial Server to Factory
Default configuration. The Industrial Serial
Server will then reboot and load the default
settings as shown below:
Default Username: admin
Default Password: admin
Default IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Default Gateway:
192.168.0.254
Buzzer Reset >1 sec Stop the buzzer