IECS-1116 Series User Manual
11
4.3 Wiring the Power Inputs
The 3-contact terminal block connector on the top panel of Industrial
EtherCAT slave I/O module is used for one DC power input. Please
followthestepsbelowto insertthepower wire.
Note
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
surethepower isOFFtopreventfromgettinganelectric
shock.
1. Insert positive and negative DC power wires into contacts 1 and 2
forPOWER.
DC Input: 9-48V , 0.5A max.PWR GND
V1+
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
1 2 3
+
GND
Note
1. The DC power input range is 9-48V DC.
2. The device provides input voltage polarity protection