IGS-5225 Series User Manual

Table Of Contents
Command Guide
-109-
Example:
To exit current mode.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # exit
Switch (config)#
4.2.65.26 flowcontrol
Command:
flowcontrol off | on
flowcontrol Traffic flow control.
off Disable flow control.
on Enable flow control.
Default:
Disable
Usage Guide:
To enable Flow-control for specific interface
Example:
To enable Flow-control for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # flowcontrol on
4.2.65.27 green-ethernet energy-detect(GG)
Command:
green-ethernet energy-detect
green-ethernet Green ethernet (Power reduction)
energy-detect Enable power saving for ports with no link partner.
Default:
N/A