Datasheet

4
IGS-6325-16P4S
SNMP v1 and v2c switch management
SSH, TLS, SSL and SNMP v3 secure access
• SNMP Management
Four RMON groups (history, statistics, alarms, and events)
SNMPtrapforinterfaceLinkUpandLinkDownnotication
• IPv6 IP address/NTP/DNS management
• Built-in Trivial File Transfer Protocol (TFTP) client
• BOOTP and DHCP for IP address assignment
• System Maintenance
Firmware upload/download via HTTP/TFTP
Reset button for system reboot or reset to factory default
Dual Images
• DHCP Relay and DHCP Option 82
• DHCP Server
• User Privilege levels control
• Network Time Protocol (NTP)
• SFP-DDM (Digital Diagnostic Monitor)
• Network Diagnositc
ICMPv6/ICMPv4 Remote Ping
Cable diagnostic technology provides the mechanism to
detect and report potential cabling issues
• PLANET NMS System and Smart Discovery Utility for
deployment management
• SMTP/Syslog remote alarm
• System Log
SMTP/SNMP Trap Event Alert
The IGS-6325-16P4S provides event alert function to help to diagnose the
abnormal device owing to whether or not there is a break of the network
connection, or the rebooting response.
Effective Alarm Alert for Better Protection
The IGS-6325 Series supports a Fault Alarm feature which can alert the users
when there is something wrong with the switches. With this ideal feature, the users
wouldnothavetowastetimendingwheretheproblemis.Itwillhelptosavetime
and human resource.
RJ45/Fiber Connection
Link Down
DC/DC Power Failure
Fault Alarm Feature
SNMP
TRAP
Mail
or
System
Log
Digital Input and Digital Output for External Alarm
The IGS-6325 Series supports Digital Input and Digital Output on its upper panel.
This external alarm enables users to use Digital Input to detect and log external
device status (such as door intrusion detector), and send event alarm to the
administrators. The Digital Output could be used to alarm the administrators if the
IGS-6325 Series’ port shows link down, link up or power failure.
Alarm Warning Alarm MessagingSecurity OK!!
Digital Output
Enclosure
Door Detector
(Door Closed)
Door Detector
(Door Open)
Enclosure
Digital Input
Uplink
RJ45 Cable
Link Down
Fiber Cable
Link Down
DC Power Failure
I/O
I/O
I/O
I/O
System
Log
SNMP
TRAP
Mail
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O