3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates an inlet power
socket and consists of one green terminal block connector within 6 contacts. Please
follow the steps below to insert the power wire.
1.Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
DC9-48V,AC24V
Max. Fault Alarm Loading: 24V, 1A
DI1 DO0 DO1DI0 GNDGND
V1+ V2+
PWR1
PWR2Alarm
DC Input: 9-48V
, 4A max.
AC Input: 24V
, 2A max.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-1: IGS-6325-5X1T Upper Panel
2.Tightenthewire-clampscrewsforpreventingthewiresfromloosening.
1 2 3 4 5 6
V1+ V1- V2+ V2-
Power 1 Power 2
Figure 3-2: Power1 & 2 Pins of Terminal Block Connector
Note
1. The wire gauge for the terminal block should be in the range
from 12 to 24 AWG.
2.Please check the AWG Ampere specification before connecting
PLANETIndustrialManagedSwitch.