Datasheet

IMG-110T
1
Industrial 1-port RS422/485 Modbus Gateway
Economic Solution for Industrial Modbus TCP/RTU/ASCII Network Integration
PLANET has added the Industrial Modbus TCP/IP Protocol to industrial management
level products to provide its easily-integrated industrial management level products with
SCADA/HMI system and other data acquisition systems in factory floors. Moreover,
the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/
IP network. PLANET industrial management level products with the Modbus TCP/IP
Protocol offer exible network connectivity solution for industrial automation environment.
To complete the industrial automation environment application solution, PLANET has
announced a first industrial level 1-port RS422/485 Modbus Gateway -- IMG-110T, a
bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol.
It features a wide operating temperature range from -40 to 75 degrees C and a compact
but rugged IP40 metal housing.
Serial Interface
One RS422/485 port with 5-contact terminal block
Cost effective for RS422/RS485 to Fast Ethernet 10/100BASE-
TX application
Supports 4-wire RS422 or 2-wire RS485 with 5-contact terminal
block operation
300bps~115200bps baud rate and non-blocking communication
Ethernet Interface
Complies with IEEE 802.3, IEEE 802.3u 10/100BASE-TX
standard
Supports 10/100BASE-TX RJ45 port with distance up to 100m
Management Function
Built-in IP-based Web interface and telnet interface for remote
management
Software Protocol supports Modbus TCP, Modbus RTU,
Modbus ASCII, IP, ARP, DHCP and DNS
Supports RTU Master, RTU Slave, ASCII Master, and ASCII
Slave four serial operation modes via management interface
Master mode supports 32 slave TCP connection requests
Slave mode supports 16 TCP master connections
Supports IP address and MAC address ltering function
PLANET Modbus Gateway utility for nding client device on
the network and related IP subnet address setting, to reset to
factory default function
PLANET Smart Discovery utility automatically nds the client
devices on the network
Firmware upgrade/conguration backup and restore via HTTP
protocol
Hardware
LED indicators for system, network and RS422/585 port
diagnostics
DIP switch on the upper panel for resetting to factory default
Wall-mount kit
Industrial Case and Installation
Wall mount-type IP40 metal case
The 2-contact terminal block connector on the top panel of
Industrial Modbus Gateway is used for DC power input (9-48V)
-40 to 75 degrees C operating temperature

Summary of content (6 pages)