User Manual
Table Of Contents
- 1. INTRODUCTION
- 2. HARDWARE INSTALLATION
- 3. INDUSTRIAL MODBUS GATEWAY MANAGEMENT
- 3.1 Overview
- 3.2 Requirements
- 3.3 Management Methods
- 3.4 PLANET Smart Discovery Utility
- 3.5 PLANET Modbus Gateway Utility
- 3.5.1 Installing PLANET Modbus Gateway Utility
- 3.5.2 PLANET Modbus Gateway Utility Menu Bar
- 3.5.3 PLANET Modbus Gateway Utility Shortcut Menu Bar
- 3.5.3.1 User Manager
- 3.5.3.2 Import Network Topology
- 3.5.3.3 Export Network Topology
- 3.5.3.4 Zoom In
- 3.5.3.5 Zoom Out
- 3.5.3.6 Search Device
- 3.5.3.7 Save Topology
- 3.5.3.8 Delete Topology
- 3.5.3.9 Batch IP Settings
- 3.5.3.10 Batch Monitoring IP Settings
- 3.5.3.11 Hide Device Tree/Show Device Tree
- 3.5.3.12 Hide Alarm List/Show Alarm List
- 3.5.3.13 Auto Refresh Topology
- 3.5.3.14 Refresh Interval
- 3.5.4 PLANET Modbus Gateway Utility Device Function
- 4. WEB MANAGEMENT
- 5. COMMAND LINE INTERFACE
- 6. COMMAND LINE MODE
- APPENDIX A
User’s Manual of IMG-110T
-9-
1.5 Product Features
Serial Interface
■ One RS422/485 port with 5-contact terminal block
■ Cost effective for RS422/RS485 to Fast Ethernet 10/100BASE-TX application
■ Supports 4-wire RS422 or 2-wire RS485 with 5-contact terminal block operation
■ 300bps~115200bps baud rate and non-blocking communication
Ethernet Interface
■ Complies with IEEE 802.3, IEEE 802.3u 10/100BASE-TX standard
■ Supports 10/100BASE-TX RJ45 port with distance up to 100m
Serial Operation Modes
■ Software Protocol supports Modbus TCP, Modbus RTU, Modbus ASCII, IP, ARP, DHCP and DNS
■ Supports RTU Master, RTU Slave, ASCII Master, and ASCII Slave four serial operation modes via management
interface
■ Master mode supports 32 slave TCP connection requests
■ Slave mode supports 16 TCP master connections
Management Function
■ Built-in IP-based Web interface and telnet interface for remote management
■ Supports IP address and MAC address filtering function
■ PLANET Modbus Gateway utility for finding client device on the network and related IP subnet address setting to
reset to factory default function
■ PLANET Smart Discovery utility automatically finds the client devices on the network
■ Firmware upgrade/configuration backup and restore via HTTP protocol
Hardware
■ LED indicators for system, network and RS422/585 port diagnostics
■ DIP switch on the upper panel for resetting to factory default
■ Wall-mount kit
Industrial Case and Installation
■ Wall mount-type IP40 metal case
■ The 2-contact terminal block connector on the top panel of Industrial Modbus Gateway is used for DC power input
(9-48V)
■ -40 to 75 degrees C operating temperature