Datasheet
IMG-120T
1
Industrial 2-port RS422/485 Modbus Gateway
Economical Solution for Industrial Modbus TCP/RTU/ASCII Network Integration
PLANET has added the Industrial Modbus TCP/IP Protocol to its IMG-120T Industrial-
level 2-port RS422/485 Modbus Gateway, an industrial management level product that
comes with SCADA/HMI system and other data acquisition systems on the factory oor.
Moreover, an industrial IT SNMP network can be upgraded to an Industrial automation
Modbus TCP/IP network without any difficulty and extra expense. The IMG-120T offers
a flexible network connectivity solution for industrial automation environment. PLANET
IMG-120T is a conversion bridge between Modbus TCP/IP Protocol and Modbus RTU/
ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C
and a compact but rugged IP40 metal housing.
The Conversion Bridge that Makes Communications Convenient
As the conversion bridge, the IMG-120T communicates well between any industrial
equipment with the Modbus RTU/ASCII Protocol and the administrator workstation that
runs the Modbus TCP/IP Protocol. The RS422/485 serial interface of the IMG-120T
provides the Modbus RTU/ASCII operation mode and various baud rate options to meet
the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/
Slave Protocol and Modbus ASCII Master/Slave Protocol.
Serial Interface
• Two RS422/485 ports with 5-contact terminal block
• Cost effective for RS422/RS485 to Fast Ethernet 10/100BASE-
TX application
• Supports 4-wire RS422 or 2-wire RS485 with 5-contact terminal
block
• 300bps~115200bps baud rate and non-blocking communication
Ethernet Interface
• Complies with IEEE 802.3, IEEE 802.3u 10/100BASE-TX
standard
• Supports 10/100BASE-TX RJ45 port with distance up to 100m
Management Function
• Built-in IP-based Web interface and telnet interface for remote
management
• Software Protocol supports Modbus TCP, Modbus RTU,
Modbus ASCII, IP, ARP, DHCP and DNS
• Supports RTU Master, RTU Slave, ASCII Master, and ASCII
Slave modes via management interface
• Master mode supports 32 slave TCP connection requests
• Slave mode supports 16 TCP master connections
• Supports IP address and MAC address ltering function
• PLANET Modbus Gateway utility for nding client device on
the network and related IP subnet address setting, to reset to
factory default function
• PLANET Smart Discovery utility automatically nds the client
devices on the network
• Firmware upgrade/conguration backup and restore via HTTP
protocol
Hardware
• LED indicators for system, network and RS422/485 port
diagnostics
• DIP switch on the upper panel for resetting to factory default
• Wall-mount kit
Industrial Case and Installation
• Wallmount-type IP40 metal case
• The 2-contact terminal block connector on the top panel of
Industrial Modbus Gateway is used for DC power input (9-48V)
• -40 to 75 degrees C operating temperature