Industrial 1-Port BNC/RJ11 to 4-Port Gigabit Ethernet Extender IVC-234GT User’s Manual
Trademarks Copyright © PLANET Technology Corp. 2018. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Energy Saving Note of the Device This power required device does not support Standby mode operation. For energy saving, please remove the power cable to disconnect the device from the power circuit.
Table of Contents 1. Package Contents........................................................................ 5 2. Hardware Introduction.................................................................. 6 2.1 Physical Dimensions.............................................................. 6 2.2 Front View............................................................................ 7 2.3 Top View.............................................................................. 8 2.4 IVC-234GT LED Indicators....
1. Package Contents Thank you for purchasing PLANET Industrial 1-Port BNC/RJ11 to 4-Port Gigabit Ethernet Extender, IVC-234GT. In the following sections, the term “Industrial Ethernet Extender” means the IVC-234GT. Open the box of the Industrial Ethernet Extender and carefully unpack it.
2. Hardware Introduction 2.1 Physical Dimensions Dimensions (W x D x H): 32 x 135 x 87.8mm Top View V1- PWR1 V1+ 1A@24V Fault PWR2 V2+ V2- Input DC12~48V, AC 24V Mounting Kit Side View Front View P1 CPE Side View Rear View P2 FAULT CO VDSL 1 2 3 4 ON CPE Inter Symm 8dB CO G.
2.2 Front View Front Panel P1 CPE P2 FAULT CO VDSL 1 2 3 4 ON CPE Inter Symm 8dB CO G.
2.3 Top View The upper panel of the Industrial Ethernet Extender consists of one terminal block connector within two DC power inputs. 1A@24V 1 2 3 4 5 6 V1+ V1- PWR1 V2+ V2Fault PWR2 Input DC12~48V, AC 24V Figure 2-3: IVC-234GT Top View 2.4 IVC-234GT LED Indicators The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system. System LED Color Function P1 Green Lights to indicate DC power input 1 has power.
100/1000BASE-T Port LED 1000 Color Green 10/100 Green Function Lit Indicates that the port is operating at 1000Mbps. Blink Indicates that the Industrial Ethernet Extender is actively sending or receiving data over that port at 1000Mbps. Off Indicates that the port is link down or 10/100Mbps. Lit Indicates that the port is operating at 100Mbps or 10Mbps. Blink Indicates that the Industrial Ethernet Extender is actively sending or receiving data over that port at 100Mbps or 10Mbps.
Note By default, the 4-position switches of the DIP switch, set at the “ON” position, are operated as “CPE”. For operating as “CO”, please turn DIP 1 switch to the “OFF” position. Then adjust other DIP switches accordingly to fulfill different network application demands. DIP-1: Mode (CO / CPE) The Master device mode, usually the CO device, is CO (Central located at the data center of ISP or enterprise to link to Office) the backbone.
DIP-3: Band Profile (Asymmetric/Symmetric) Asymmetric The asymmetric mode provides more bandwidth than the other side. This mode provides the highest bandwidth in short range. Symmetric With the G.997 band plan supported, the symmetric mode can provide almost the same rate of downstream and upstream. DIP-4: SNR (Signal Noise Ratio) Margin When the SNR margin is selected, the system provides 12dB/8dB SNR margin for all usable loop lengths.
3. Product Specifications Product IVC-234GT Hardware Specifications TP interface 4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports 1 BNC female Ethernet over Coaxial BNC VDSL Cabling Coaxial cable: 75 ohm RG-6/U cable, less than12Ω/1000 ft RG-59/U cable, less than 30Ω/1000 ft. Maximum Max. 1200m with data transmission Distance (3,937ft.) RJ11 Functionality 1 VDSL2 RJ11 female phone jack Twisted-pair telephone wires (AWG-24 or better) up to 1.2km (3,937ft.) DIP-1 Select CO or CPE mode DIP-2 Select G.
System Specifications VDSL Compliance VDSL-DMT ITU-T G.993.1 VDSL ITU-T G.997.1 ITU-T G.993.2 VDSL2 (Profile 17a/30a Support) ITU-T G.993.5 G. Vectoring ITU-T G.998 G.INP Standards Conformance Standards Compliance IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3ab Gigabit Ethernet ITU-T G.993.1 VDSL ITU-T G.997.1 ITU-T G.993.2 VDSL2 (Profile 17a/30a Support) ITU-T G.993.5 G.Vectoring and G.INP ITU-T G.
4. Applications The Industrial Ethernet Extender does not require any software configuration. Users can immediately use any feature of this product simply by attaching the cables and turning the power on. There are some key limitations on the Industrial Ethernet Extender. Please check the following items. 4.1 Point-to-Point Application -- LAN to LAN Connection One set of the Industrial Ethernet Extender could be used to link two local area networks that are located in different places.
LAN to LAN Connection LAN 1 LAN 2 1 2 3 4 1 2 3 4 ON ON PC PC VDSL2 IVC-234GT (CO) Ethernet over Coaxial IVC-234GT (CPE) Up to 1200m VDSL2 VDSL2 Coaxial Cable 1000BASE-T UTP Connecting Standalone PC Refer to the following procedures to set up the Industrial Ethernet Extender LAN to LAN connection. 1. [LAN1] Set the Industrial Ethernet Extender at LAN 1 in the CO mode from the DIP switch. 2. [LAN2] Set the Industrial Ethernet Extender at LAN 2 in the CPE mode from the DIP switch. 3.
4.2 Point to Multi-point Application (IP surveillance) Applications of IP Surveillance LAN 1 LAN 2 IP Camera 1 2 3 4 1 2 3 4 ON ON L2+ Switch IP Camera VDSL2 NVR IVC-234GT (CPE) Ethernet over Coaxial IVC-234GT (CO) IP Camera IP Camera Up to 1200m VDSL2 VDSL2 Coaxial Cable 1000BASE-T UTP Building a IP surveillance system Refer to the following procedure to set up many pairs of IVC-234GT to IP surveillance system. 1.
5. Installations 5.1 Wiring the Power Inputs The 6-contact terminal block connector on the top panel of Industrial Ethernet Extender is used for two DC redundant power inputs. Please follow the steps below to insert the power wire. Caution When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock. 1.
5.2 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Ethernet Extender will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
5.3 DIN-rail Mounting Installation The DIN-rail bracket is screwed on the Industrial Ethernet Extender when out of factory. Please refer to the following steps for DIN-rail mounting: Step 1: Screw the Extender. DIN-rail bracket on the Industrial Ethernet Step 2: Lightly insert the bottom of the switch into the track.
Step 3: Make sure the DIN rail is tightly secured on the track. Step 4: Please refer to the following procedure to remove the Industrial Ethernet Extender from the track. 1 2 Step 5: Lightly pull out the bottom of DIN rail for removing it from the track.
5.4 Wall-mount Plate Mounting To install the Industrial Ethernet Extender on the wall, please follow the instructions described below. Step 1: Remove the DIN-rail bracket from the Industrial Ethernet Extender with a screwdriver. Step 2: Place the wall-mount plate on the rear panel of the Industrial Ethernet Extender. Step 3: Use the screws to screw the wall-mount plate on the Industrial Ethernet Extender.
6. Performance Table Industrial Ethernet Extender Upstream/Downstream Performance with RJ11 connection Interleave (Upstream/Downstream) CO DIP Switch Distance (meter) Asymmetric Symmetric 8dB 12dB 8dB 12dB 200 93/190 85/174 143/148 132/136 400 67/164 59/146 118/119 103/104 600 38/116 28/94 71/75 59/60 800 24/59 22/49 49/36 38/27 1000 9/45 7/40 21/25 15/24 1200 6/30 3/28 16/24 6/20 G.
Industrial Ethernet Extender Upstream /Downstream Performance with BNC connection Interleave (Upstream/Downstream) CO DIP Switch Distance (meter) Asymmetric Symmetric 8dB 12dB 8dB 12dB 200 84/184 75/169 131/144 125/128 400 49/148 54/128 93/118 89/99 600 36/100 26/80 77/66 64/53 800 21/50 17/39 44/30 37/26 1000 7/42 5/29 20/25 19/28 1200 5/27 3/28 13/27 15/20 G.
7. Troubleshooting SYMPTOM: VDSL LNK LED does not light up after wire is connected to the VDSL port. CHECKPOINT: 1. Verify the length of the coaxial cable (not more than 1.2km) connected between the two IVC-234GT units. Please also try to adjust the DIP switch of the IVC-234GT to the other SNR mode. 2. Please note you must use one IVC-234GT in CO mode and the other IVC-234GT in CPE mode to make connection to each other work. SYMPTOM: TP LED does not light up after cable is connected to the port.
8. FAQs Q1: What is VDSL2? A1: VDSL2 (Very High-Bit-Rate Digital Subscriber Line 2), G.993.2 is the newest and most advanced standard of xDSL broadband wire line communications. Designed to support the wide deployment of Triple Play services such as voice, data, high definition television (HDTV) and interactive gaming, VDSL2 enables operators and carrier to gradually, flexibly, and cost efficiently upgrade the existing xDSLinfrastructure.
9. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw Copyright © PLANET Technology Corp. 2018. Contents are subject to revision without prior notice.
EC Declaration of Conformity For the following equipment: *Type of Product : IP30 Industrial Ethernet Extender, 4-Port 10/100/1000T RJ45, 1-Port BNC, 1-Port RJ11 *Model Number : IVC-234GT * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan, R.O.C.