<Instance> The MEP instance number.
down This MEP is a Down-MEP
domain The domain of the MEP
evc This MEP is a EVC domain MEP.
port This MEP is a Port domain MEP.
vlan This MEP is a VLAN domain MEP.
flow The flow instance that the MEP is related to.
<flow > The flow instance number when not in the port domain.
vid In case the MEP is a port Up-MEP or a EVC customer MIP the VID must be given.
<Vid : vlan_id> The port Domain MEP VID. This is required for a Port Up-MEP.
Default:
None
Usage Guide:
To configure Down-MEP of MEP.
Example:
To configure Down-MEP of MEP 1 as below table
Switch# configure terminal
Switch (config)# mep 1 down domain port flow 1 level 0 interface GigabitEthernet 1/1
4.2.134 mep <Instance> lb
Command:
mep <Instance> lb <prio> [ dei ] [ multi | { uni { { mep-id <mepid> } | { mac
<mac> } } } ] count <count> size <size> interval <interval>
mep Maintenance Entity Point
<Instance> The MEP instance number.
lb Loop Back
<Prio : 0-7> Priority in case of tagged OAM. In the EVC domain this is the COS-ID.
count The number of LBM PDU to send in one loop test. The value 0 indicate infinite transmission (test behavior). This
is HW based LBM/LBR and Requires VOE.
<Count : uint> Number of LBM PDU to send value
size The number of bytes in the LBM PDU Data Pattern TLV