SPECIFICATION
480W Single Output Industrial DIN RAIL
NDR - 4 8 0 ser i e s
File Name:NDR-480-SPEC 2015-10-29
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1500ms, 100ms/23
0VAC 3000ms, 100ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
4.8A/115VAC 2.4A/230VAC
29 ~ 33V
92.5%
56 ~ 65V
92.5%
20A/115VAC 35A/230VAC
<2mA / 240VAC
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
Ul508, TUV EN60950-1 approved
;(meet EN60204-1)
Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A
-20 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
146.8K hrs min. MIL-HDBK-217F (25℃)
85.5*125.2*128.5mm (W*H*D)
1.5Kg; 8pcs/13Kg/0.9CUFT
NDR-480-24 NDR-480-48
24V 48V
20A 10A
0 ~ 20A 0 ~ 10A
480W 480W
150mVp-p 150mVp-p
24 ~ 28V 48 ~ 55V
±1.0% ±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG
:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
℃
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com
)
EMC IMMUNITY
EMC EMISSION
105 ~ 130% rated output power
Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.94/230VAC at full load