User Manual

273
Users Manual of XGS-6350-24X4C
Switch_config_ring2#hello-time 4
Switch_config_ring2#fail-time 12
Exits from the node configuration mode:
Switch_config_ring2#quit
The following commands are used to set the primary port and secondary port of node 2:
Switch_config#interface gigaEthernet 0/1
Switch_config_g0/1#mether-ring 2 domain 1 primary-port
Switch_config_g0/1#switchport mode trunk
Switch_config_g0/1#quit
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 2 domain 1 secondary-port
Switch_config_g0/2#switchport mode trunk
Switch_config_g0/2#quit
Configuring switch S6:
The following commands are used to set the major-ring master node, node 1:
Switch_config#mether-ring 1 domain 1
Switch_config_ring1#master-node
Switch_config_ring1#major-ring
Switch_config_ring1#control-vlan 2
The following commands are used to set the time related parameters:
Switch_config_ring1#hello-time 4
Switch_config_ring1#fail-time 12
Exits from the node configuration mode:
Switch_config_ring1#quit
The following commands are used to set the transit port of node 1:
Switch_config#interface gigaEthernet 0/1
Switch_config_g0/1#mether-ring 1 domain 1 primary-port
Switch_config_g0/1#switchport mode trunk
Switch_config_g0/1#quit
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 1 domain 1 secondary-port
Switch_config_g0/2#switchport mode trunk
Switch_config_g0/2#quit
The following commands are used to set the sub-ring assistant node, node 2:
Switch_config#mether-ring 2 domain 1
Switch_config_ring2#assistant-node
Switch_config_ring2#sub-ring
This can be omitted
Switch_config_ring2#control-vlan 2