User Manual
315
Users Manual of XGS-6350-24X4C
case, while the window size ranges between
1 and 60 on a 100M Ethernet interface and
its default value is 1 in this case.
Step5 ethernet oam link-monitor
frame {threshold {high
{ symbols |none} | low
{symbols}} | window
symbols}
Sets the high and low thresholds of the error
frame event, which triggers the link events
of error frame.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 65535 and
its default value is none.
The threshold high parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 65535 and
its default value is 1.
The window parameter is used to configure
the window size of the round-query period.
Its unit is second. It ranges between 1 and
60 and its default value is 1.
Step6 ethernet oam link-monitor
frame-period {threshold
{high { symbols |none} | low
{symbols}} | window
symbols}
Sets the high and low thresholds of the
period event of error frame, which triggers
the link events of error frame period.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 65535 and
its default value is none.
The threshold high parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 65535 and
its default value is 1.
The window parameter is used to configure
the window size of the round-query period.
The unit of the window size is the number of
the 14881 frames. The window size ranges
between 100 and 6000 on a 1000M
Ethernet interface and its default value is
100 in this case, while the window size
ranges between 10 and 600 on a 100M
Ethernet interface and its default value is 10
in this case.