SDS

Material name: Plasti Dip Spray 1 Gal Florecent Green
823 Version #: 01 Issue date: 07-07-2014
SDS US
4 / 12
7. Handling and storage
Precautions for safe handling
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Vapors may form explosive mixtures with air. Do not handle, store or open near
an open flame, sources of heat or sources of ignition. Protect material from direct sunlight.
Minimize fire risks from flammable and combustible materials (including combustible dust and
static accumulating liquids) or dangerous reactions with incompatible materials. Handling
operations that can promote accumulation of static charges include but are not limited to: mixing,
filtering, pumping at high flow rates, splash filling, creating mists or sprays, tank and container
filling, tank cleaning, sampling, gauging, switch loading, vacuum truck operations. Take
precautionary measures against static discharges. All equipment used when handling the product
must be grounded. Use non-sparking tools and explosion-proof equipment. Do not breathe mist or
vapor. Avoid contact with eyes, skin, and clothing. Avoid contact during pregnancy/while nursing.
Avoid prolonged exposure. Do not taste or swallow. When using, do not eat, drink or smoke.
Provide adequate ventilation. Should be handled in closed systems, if possible. Wear appropriate
personal protective equipment. Wash hands thoroughly after handling. Observe good industrial
hygiene practices. Avoid release to the environment. Do not empty into drains.
For additional information on equipment bonding and grounding, refer to the Canadian Electrical
Code in Canada, (CSA C22.1), or the American Petroleum Institute (API) Recommended Practice
2003, "Protection Against Ignitions Arising out of Static, Lightning, and Stray Currents" or National
Fire Protection Association (NFPA) 77, "Recommended Practice on Static Electricity" or National
Fire Protection Association (NFPA) 70, "National Electrical Code".
Conditions for safe storage,
including any incompatibilities
Store locked up. Keep away from heat, sparks and open flame. Prevent electrostatic charge
build-up by using common bonding and grounding techniques. Avoid spark promoters. Eliminate
sources of ignition. Ground/bond container and equipment. These alone may be insufficient to
remove static electricity. Store in original tightly closed container. Store in a cool, dry place out of
direct sunlight. Store in a well-ventilated place. Refrigeration recommended. Store away from
incompatible materials (see Section 10 of the SDS). Keep in an area equipped with sprinklers.
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
Components
Type
Value
Form
CALCIUM CARBONATE
(CAS 1317-65-3)
METHYL ETHYL KETONE
(CAS 78-93-3)
N-HEXANE (CAS 110-54-3)
US. OSHA Table Z-2 (29 CFR 1910.1000)
PEL
5 mg/m3 Respirable fraction.
15 mg/m3 Total dust.
PEL
590 mg/m3
200 ppm
PEL
1800 mg/m3
500 ppm
Components
Type
Value
TOLUENE (CAS 108-88-3)
US. ACGIH Threshold Limit Values
Ceiling 300 ppm
TWA
200 ppm
Components
Type
Value
METHYL ETHYL KETONE
(CAS 78-93-3)
N-HEXANE (CAS 110-54-3)
TOLUENE (CAS 108-88-3)
STEL
300 ppm
TWA
200 ppm
TWA
50 ppm
TWA
20 ppm
US. NIOSH: Pocket Guide to Chemical Hazards
Components
Type
Value
Form
CALCIUM CARBONATE
(CAS 1317-65-3)
METHYL ETHYL KETONE
(CAS 78-93-3)
TWA
5 mg/m3 Respirable.
10 mg/m3 Total
STEL
885 mg/m3
300 ppm