Operation Manual

DieSetInstallation(cont)
3) PositiondiesetasshowninFigure7andslideintotoolframe.
Ensuretopdiescrewhead(a)isencapsulatedbyupperdiecontrol
arms.
4) HandtightenthumbscrewbyrotatingclockwiseperFigure8.
5) Squeezeframehandlestocompleteafullratchetcycle.
6) Toolisreadyforuse.
Figure7
a
Figure8
6
DieSetReplacement
1) Squeezeframehandlesuntiltheupperdiecontrolarms,Figure9(a)
arevisibleinthediecavity.
Note:Tworatchetclicksshouldbeheardwhenproperlypositioned.
2) Loosenthumbscrew(b)byrotatingcounterclockwise.Ensureno
portionofthescrewispresentinthediecavity.
3) Slidedieoutoftoolframebypushingfromtheoppositesideshown
inFigure9.
4) Reinstalldiefollowingthe“DieSetInstallation”steps16shownon
page5and6.
DieCavity
a
b
Figure9
7