Use and Care Manual
12
Toinspectorreplacethebulbs,rstunplugthepowercordfromtheoutlet.Locatetheaccesspanel
on the back of the stove. Remove the screws and the panel. Check the bulbs to be sure they are
ngertightandinworkingorder.Replaceanydamagedorfaultybulbs.Reattachtheaccesspanel.
Do not operate this heater without the access panel in place. Do not remove the back cover of this
heater. There are no serviceable parts inside.
CARE AND MAINTENANCE
Cleaning
Always turn the heater OFF and unplug the power cord from the outlet before cleaning. Use a vacu-
umordustertoremovedustanddirtfromtheheaterandventareas.Tomaintainthenish,cleanwith
a soft, slightly damp cloth and buff with a dry cloth. Never use abrasive cleansers, liquid sprays, or
any cleaner that could scratch the surface.
Neverdragtheunitacrossaoor.Theaddedstressfromdraggingtheunitmaycausethelegs
to break.
Glass Information (some models)
1. Under no circumstances should this product be operated with broken glass.
2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the glass.
4. This product uses tempered glass. Replacement of the glass supplied by the manufacturer
shouldbedonebyaqualiedserviceperson.
Light Bulb Inspection and Replacement
Theameeffectiscreatedbytwo40-WattlightbulbswithanE-12(small)socketbase.Useonlythis
typeoflightbulb.Iftheameeffectdoesnotwork,thebulbsmayhavecomelooseorbeendamaged
during shipping.
WARNING: Light bulbs become very hot during use. Allow at least 10 minutes for the
bulbs to cool before touching.
WARNING: Do not exceed 40 watts per bulb. Use of higher rated
bulbsmayresultinare,causingpropertydamageorpersonalinjury.
Maintenance of Motors
WARNING: Always disconnect the appliance from the main power supply and allow it to
cool before any servicing operation.
Themotorsusedonthefanheaterandameeffectarepre-lubricatedforextendedbearinglifeand
require no further lubrication. However, periodic cleaning/vacuuming of the appliance around the air
intake and exhaust, as well as the fan heater is recommended. For heavy or continuous use, periodic
cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the
fanforfreemovementandfordebrisrestrictingairow.Ifthefandoesnotmovefreely,theunitmust
be turned off and the fan replaced immediately in order to prevent further damage to the unit.