Instructions / Assembly

16
The maximum inlet gas supply pressure: 250 psi /1750 kPa. The minimum inlet gas supply pressure:
5 psi /35kPa. The minimum hourly of 10000 Btu /2.93 kW is required input rating for an appliance for
automatic operation at ratings less than full input rating.
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
DO NOT obstruct the ow of combustion air and ventilation air to the re pit. The propane cylinder
must be arranged for vapor withdrawal and equipped with a listed overlling prevention device.
Please use the proper cylinder orientation to provide vapor withdrawal. NOTE: The cylinder must be
fully upright for the cylinder to have vapor withdrawal only.
ASSEMBLY INSTRUCTIONS
CAUTION
a. Do not store a spare LP-gas cylinder under or near this appliance.
b. Never ll the cylinder beyond 80 percent full.
c. If the information in (a) and (b) is not followed exactly, a re causing death or serious injury
may occur.
The pressure regulator and hose assembly supplied with the appliance must
be used. The installation must conform with local codes, or in the absence of
local codes, with national fuel gas code, ANS Z223.1/NFPA54, natural gas
and propane Installation Code, CSA B149.1, or propane storage and handling
code, B149.2.
CORRECT WRONG WRONG
12. Seat and position propane cylinder in the Bottom
Plate (L) and fasten cylinder with strap as shown
in the gure.
N
L