Installation Guide
7077-171 • July 10, 2012
3
A. Appliance Certication
C. Glass Specications
E. BTU & Efciency Specications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please contact
GHP for replacement glass.
B. Mobile Home Approved
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, (UM) 84-HUD,
*BTU input will vary, depending on the brand of fuel you
use in your stove.**Heating capacity depends on climate
zone, structure layout, insulation, windows, etc.
MODEL: PH35PS
Particulate Emissions
Rating:
0.34 grams / hr
*BTU Input: 11,000 - 35,000 / hr
Efciency: 78%
**Heating Capacity: 750 to 1450 sq. ft. depending
on climate zone
Hopper Capacity:
(Approx)
40 lbs
Fuel: Wood Pellets
Shipping Weight: 160 lbs
Series: PH35PS, PH50PS, PH50CABPS
Laboratory: Intertek
Report No.
Type: Solid Fuel Room Heater/Pellet
Fuel Burning Type
Standard: ASTM E1509-04 and ULC S627-
00, Room Heater Pellet Fuel
Burning type and (UM) 84-HUD,
Mobile Home Approved.
1
Listing and Code Approvals
These heaters meet the US Evironmental Protection Agency’s
Emission limits for pellet heaters. Under specic condi-
tions the PH35PS stove has shown to deliver heat at rates
ranging from 9,550 to 25,080 BTU/hr and the PH50PS and
PH50CABPS stoves have shown to deliver heat at ranges
between 9,250 and 32,400 BTU/hr.
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home oor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the
frame of the mobile home with #8 copper ground wire,
and use only listed double-wall connector pipe.
• Outside Air Kit provided with each unit must be in-
stalled in a mobile home installation.
WARNING! Risk of Fire! GHP disclaims any responsibility
for, and the warranty and agency listing will be voided by the
below actions.
DO NOT:
• Installoroperatedamagedappliance
• Modifyappliance
• Installotherthanasinstructedbythemanufacturer.
• Operatetheappliancewithoutfullyassemblingall
components
• Overre
• Installanycomponentnotapprovedbythe
manufacturer
• InstallpartsorcomponentsnotListedorapproved
• Disablesafetyswitches
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
D. Electrical Rating (On High)
PH35PS Series: 115 VAC, 60 Hz, Start 2.6 Amps,
Run 0.9 Amps
PH50PS Series: 115 VAC, 60 Hz, Start 2.6 Amps,
Run 0.9 Amps
PH50CABPS Series: 115 VAC, 60 Hz, Start 2.6 Amps,
Run 0.9 Amps
MODEL: PH50PS / PH50CABPS
Particulate Emissions
Rating:
.69 grams / hr
*BTU Input: 11,000 - 50,000 / hr
Efciency (B415): 78%
**Heating Capacity: 1225 to 2200 sq. ft. depending
on climate zone
Hopper Capacity:
(Approx)
80 lbs
/
120 lbs
Fuel: Wood Pellets
Shipping Weight:
180 lbs
/
200 lbs