Installation Guide
7077-171 • July 10, 2012
34
12
Reference Materials
13. Snap Disc (Back Burn Protector) 200°F
Snap disc is mounted on the back of the auger tube in the
center of the appliance and has a reset button. There are two
grey wires connected to it. To access it remove the right side
panel. If the re tries to burn back into the feed system or push
exhaust up the feed tube, this snap disc will shut the entire
system off. Unplug the stove prior to resetting.
14. Vacuum Switch
The vacuum switch is located on the lower right side of the
appliance behind right side panel. There are two red wires
attached to it. This switch turns the feed system on when
vacuum is present in the rebox. The vacuum switch is a safety
device to shut off the feed motor if the exhaust or the heat
exchanger system is dirty or plugged or if the rebox door is
open or exhaust blower failure.
15. Outside air inlet
The outside air tube can be attached to the 2” OD inlet tube
mounted to the rear of the rebox. To extend the hose outside
the unit there is a knockout plate that must be removed.
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF THE
APPLIANCE.
1. Control Board
The control board is located on the right side of the appliance
behind the lower right side panel.
2. Convection Blower
The convection blower is mounted in the rear of the unit. It
pushes air up the rear of the rebox, across the top and out
the front. As the air moves past the rebox it is heated.
3. Exhaust Blower
The exhaust blower is mounted on the left side of the
appliance. The exhaust blower is designed to pull the exhaust
from the appliance and push it out through the venting system.
4. Feed System
The feed system can be accessed in two areas. To access
the auger spring, remove the cover in the hopper. To remove
the feed motor, remove the side panel and motor cover plate
in the rear of the unit.
5. Firepot
The repot is made of a combination of stainless steel and
heavy duty cold rolled steel. It is removable to aid in cleaning.
6. Fuse
The fuse is located on the control board. The fuse will blow
should a short occur and shut off power to the appliance.
7. Dial Control
The heat output switch is located on the upper right back
panel. The function of the heat output switch is to regulate
the burn rates; low, medium and high settings.
8. Hopper Switch
The hopper switch is located in the upper right hand corner
of the hopper. This switch is designed to shut down the feed
motor whenever the hopper lid is opened.
9. Igniter
The igniter is mounted in the chamber in the rear of the rebox
below the convection blower. Combustion air travels over the
red hot igniter creating super heated air that ignites the pellets.
10. Power Supply
The power cord connector in the rear of the unit. Check the
wall receptacle for 120 volt, 60 Hz (standard current). Make
sure the outlet is grounded and has the correct polarity. A
good surge protector is recommended.
11. Exhaust Probe
The exhaust probe is mounted to the side of the exhaust
outlet in the rear of the unit. It senses the temperature of the
exhaust and allows the control system to make decisions.
12. Ambient Probe
The ambient probe is located in the back panel. It has extra
wire to increase distance from appliance if needed.
A. Component Function
E