N. Trim Adjustment
The small dial located below the primary dial control
used to operate the appliance is used for elevation
changes. The factory default setting for this dial is
0. See the installation section for more information
regarding installations at elevations higher than 4000
feet.
J. Ignition Cycles
1. At the beginning of each ignition cycle, it is normal to see
some smoke in the rebox. The smoke will stop once
the re starts.
2. The convection blower will automatically turn on after
your appliance has been burning for approximately 10
minutes.
This blower transfers heat from your appliance into the
room, and will continue to run even after the unit has
shutdown. It will turn off after the exhaust temperature
has cooled.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens the empty hopper alarm
will be triggered.
2
User Guide: General Operating Information
WARNING! RISK OF FIRE! Keepcombustiblematerials,
gasolineandotherammablevaporsandliquidsclearof
appliance.
• DoNOTstoreammablematerialsintheappliance’s
vicinity.
• DoNOTusegasoline,lanternfuel,kerosene,charcoal
lighteruidorsimilarliquidstostartor“freshenup”are
in this heater.
Keepallsuchliquidswellawayfromtheheaterwhileitisin
useascombustiblematerialsmayignite.
M. Clear Space
WARNING! RISK OF FIRE! DoNOTplacecombustible
objectsinfrontortothesidesoftheappliance.Hightem-
peraturesmayigniteclothing,furnitureordraperies.
NOTICE: Clearancesmayonlybereducedbymeansap-
provedbytheregulatoryauthorityhavingjurisdiction.
Mantel:
Avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
K. Running in Minimum or Maximum
When the dial control is set to run on the minimum or
maximum setting, the appliance will continue to run
without regard to the actual temperature in the room.
The appliance will shut off only if the dial control is set to
a different setting or there is an error such as an empty
hopper.
When running on minimum or maximum it is important
to follow the daily cleaning activities especially cleaning
the repot. Failure to do so will reduce the performance
of the appliance.
L. Running in the Automatic Mode
When the dial control is set to run in the automatic mode
the unit will adjust the actual burn rate based on the
difference between the room temperature as sensed by
the probe located in the rear of the unit and the desired
comfort level as set on the dial control.
The comfort level range is from 65 degrees Fahrenheit
to 82 degress Fahrenheit.
Once the desired comfort level is achieved the appliance
will automatically shut down and turn off. When the
temperature in the room drops 3 degrees below the
desired comfort level, the appliance will automatically
restart.