Firebox Dimensions and Firebox Location
LOCATION OF FIREBOX
Carefully select the best location for installation of your
vent-free rebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles must be main-
tained.
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers for
forced air furnaces/air conditioners, windows or doors.
• Installation must provide adequate ventilation and com-
bustion air.
• Location should be out of high trafc or windy or drafty
areas.
DO NOT INSTALL WHERE CURTAINS, FURNITURE,
CLOTHING OR OTHER FLAMMABLE OBJECTS ARE
LESS THAN 42” FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent-free rebox
or restrict the ow of combustion and ventilation air.
• Minimize modications to existing construction. Refer to
Figure 2 below for location suggestions.
• Do not install in the vicinity where gasoline or other
ammable liquids may be stored. The vent-free rebox
must be kept clear and free from these combustible
materials.
Figure 1 - Minimum Hearth Dimensions
W
2
17.0
16.5
20.7
3.5
34.1
W1
FIREBOX DIMENSIONS
DIMENSION
PHZCF32C / PHZCF 32R PHZCF36C / PHZCF 36R PHZCF42C / PHZCF42R
W1
35 7/8" 39 7/8" 45 7/8"
W2
32 3/16" 36 3/16" 42 3/16"
W3
18 1/16" 22 1/16" 28 1/16"
W3
Fig. - Location of Firebox
Figure 2 - Location of Firebox