Installation Guide

4
SAFETY INFORMATION
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is
not convertible for use with other gases.
2.
Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3. If you smell gas
• shut o gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions
• if you cannot reach your gas supplier, call the re department
4. This replace shall not be installed in a bedroom or bathroom.
5. Do not use this replace as a wood-burning replace. Use only the logs provided with the replace.
6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these
added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into
the control area of replace.
7. This replace is designed to be smokeless. If logs ever appear to smoke, turn o replace and
call a qualied service person. Note: During initial operation, slight smoking could occur due to log
curing and replace burning manufacturing residues.
8. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 32.
9. Before using furniture polish, wax, carpet cleaner or similar products, turn replace o. If heated,
the vapors from these products may create a white powder residue within burner box or on adjacent
walls or furniture.
10. This replace needs fresh air ventilation to run properly. This replace has an Oxygen Depletion
Sensing (ODS) safety shuto system. The ODS shuts down the replace if not enough fresh air is
available. See Air for Combustion and Ventilation, page 9-11. If replace keeps shutting o, see
Troubleshooting, page 34.
11. Do not run replace
• where ammable liquids or vapors are used or stored.
• under dusty conditions.
12. Do not use this replace to cook food or burn paper or other objects.
13. Never place any objects in the replace or on logs.
14. Do not use replace if any part has been under water. Immediately call a qualied service technician
to inspect the room replace and to replace any part of the control system and any gas control which
has been under water.
15. Turn o and unplug replace and let cool before servicing. Only a qualied service person
should service and repair replace.
16. Operating replace above elevations of 4,500 feet could cause pilot outage.
17.
Do not operate replace if log is broken. Do not operate replace if log is chipped (dime-sized or larger).
18. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.
19. Provide adequate clearances around air openings.
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and
replace gas piping, gas utilization equip-
ment or accessories, and repair and equip-
ment servicing. The term "qualied agency"
means any individual, rm, corporation, or
company that either in person or through a
representative is engaged in and is respon-
sible for:
a) Installing, testing, or replacing gas piping or
b)Connecting, installing, testing, repairing, or
servicing equipment; that is experienced in
such work; that is familiar with all precautions
required; and that has complied with all the re-
quirements of the authority having jurisdiction.