Installation Guide

13
INSTALLATION
1. Remove Blower Access Panel.
FF
2. Mount Blower (B) onto bottom of
Fireplace Top using 4 screws (F).
3. Attach Power Cord (A) to Blower
Access Panel.
4. Attach Temperature Sensor (C) to
the Combustion Top using 2 sheet
metal screws.
1
2
3
Access Panel
Screws
Power Cord
Access Panel
WARNING: This optional blower is equipped with a three-prong (grounding) plug for
your protection against shock hazard and must be plugged directly into a properly
grounded three-prong receptacle.
Firebox must be disconnected from gas supply and removed from mantel before
installing fan accessory. Contact a qualied service person to do this.
BLOWER INSTALLATION (OPTIONAL)
4
Sheet
Metal
Screws
Senser
Bracket
Combustion Top
Mounting Holes